Specifications

11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
14
PATENTS PENDING
ADJUSTMENTS
MAT SWITCH ADJUSTMENT
2. Measure the height of the
Threshhold Plate as shown in
(FIG. 14-1B). If the height is
not 5/8”, do step 3. If the height
is already 5/8”, skip step 3, and
go on to step 4.
LIFT AT GROUND LEVEL
(RH SIDE SHOWN)
FIG. 14-1A
ILLUMINATED
POWER SWITCH
HEIGHT MEASUREMENT
(RH SIDE SHOWN)
FIG. 14-1B
1. Make sure power switch (FIG.
14-1A) is turned on
and illuminated. Low-
er Lift to the ground
(FIG. 14-1A).
5/8”
NOTE: Do this procedure if structure of the Lift is undamaged and:
• The Controller reads “MAT ERR” when the Threshold Plate is unoccupied
and Platform is below oor level.
• The Threshold Warning Beacons and Threshold Warning Alarm are on
when Threshold is unoccupied and Platform below oor level.
• The Threshold Warning Beacons and Threshold Warning Alarm will not turn
on when Threshold is occupied and Platform below oor level.
• The MAT switch or Threshold Plate are removed & replaced.
The adjustment is done correctly if:
• The Controller does not read “MAT ERR” when the Threshold Plate is unoc-
cupied and Platform is below oor level.
• The Threshold Warning Beacons and Threshold Warning Alarm are on
when Threshold is unoccupied and Platform below oor level.
• The Threshold Warning Beacons and Threshold Warning Alarm turn on
when Threshold is occupied and Platform below oor level.