Specifications

11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
27
PATENTS PENDING
LIFT TO
REMOVE
COVER
HEX NUT
LOWERING SWITCH ADJUSTMENT SCREW
FIG. 27-2B
ADJUSTMENT
SCREW
CAP SCREW
(ALLEN HEAD)
LOWER SWITCH ADJUSTMENT SCREW
FIG. 27-3
3. Remove cover from tower
(FIG. 27-2A).
REMOVING COVER
(RH TOWER SHOWN)
FIG. 27-2A
LOCK NUT
(BOTTOM OF
SCREW)
ADJUSTMENT
BLOCK
4. Loosen lock nut (FIG. 27-2B) just
enough to turn adjustment screw.
CW TO
ACTIVATE SWITCH
CCW TO
DEACTIVATE SWITCH
6. Turn adjustment screw CW (FIG. 27-
3) until switch just clicks (activates). If
switch is already activated, turn ad-
justment screw CCW until switch just
clicks (deactivates). Then turn screw
CW until it just clicks (activates).
5. Loosen hex nut and allen head cap
screw to release adjustment block
(FIG. 27-2B).
NOTE: The LOWERING switch
adjustment screw is always
on the opposite side of the
Lift as the Pump Cover (FIG.
27-1).
RH PUMP
LH PUMP
ADJUSTMENT
SCREW
WHERE TO FIND ADJUSTMENT SCREW
FIG. 27-1