Specifications

11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
34
PATENTS PENDING
1/8” TRAVEL
(CONTACTS
OPEN)
1. Position the Lift at oor level so the Inboard
Rollstop is open (FIG. 34-1A).
2. The correct indication for switch is:
With plunger pushed 1/8” (FIG. 34-
1B), switch activates with a “click”
and contacts are closed. Switch must
remain activated beyond the 1/8” of
travel and plunger must always oper-
ate smoothly. If plunger requires less
or more distance than 1/8” (to acti-
vate switch), do step 3.
LIFT AT FLOOR LEVEL
(LH SIDE SHOWN)
FIG. 34-1A
3. Loosen switch attaching screws and nuts.
Next move switch (FIG. 34-1C) to increase
or decrease the plunger travel needed to
close switch contacts. Tighten switch attach-
ing screws and nuts. Then repeat steps 2 and
3 until switch activates correctly.
INCREASE
DECREASE
PLUNGER TRAVEL
FIG. 34-1B
ADJUSTING SWITCH
FIG. 34-1C
PLUNGER
PLUNGER
SWITCH
SWITCH
SCREWS & NUTS
(2 PLACES)
INBOARD ROLLSTOP
(SHOWN OPEN)
INBOARD SWITCH ADJUSTMENT
NOTE: Do this procedure if structure of the Lift is undamaged and:
• The Controller reads “STOW SW” when Inboard Rollstop is locked in the up
position.
• Inboard Switch is removed & replaced.
The adjustment is done correctly if:
• The Controller does not read “STOW SW” when the Inboard Rollstop is
locked in the up position.