Troubleshooting guide

Manual CT60 & CT80 April 2008
www.max-power.com 15
23. TROUBLESHOOTING GUIDE
Before contacting your nearest Max Power distributor, please check the below
troubleshooting guide.
Problem Check
The control panel does not light
up
Check the 6 wire connector behind the joystick
Check the thruster's electronic control box 6 wire
connector
Check the circuit breaker / switch in the boat's
main DC distribution panel
Check the control box's power fuse (8 A)
The relay is clicking but the motor
is not running
Check the motor's power fuse
Check the main battery isolator
Check the internal relay contacts
Check battery conditions and connections
The motor is running but the
thruster is not working
Check the propellers are fitted
Check the motor / drive leg assembly
Check that the tunnel is not obstructed or the
propellors blocked
The thruster lacks power
Check the propellers are fitted
Check the size of the batteries
Check the batteries are sufficiently charged
Check the connections are tightened correctly
Check the power cables sections
(See p. 6 : Recommended cable sections)
24. WORLDWIDE DISTRIBUTION NETWORK
To locate the nearest Max Power distributor, please consult the section
"Worldwide Distribution" on our website: www.max-power.com