User's Manual

MaxStream, Inc. 24XStream Wireless Module Manual v2.8
23
AT
Command
Binary
Command #
Description Parameters
# Bytes
Returned
Factory
Default
LH 12 Transmit header time Time in tenths of seconds for
the long header.
Range: 0 – 0xFF
1 1
FH 13 Force header on next transmit NA NA NA
RE 14 Restore default configuration NA NA NA
ER 15 Set Receive Error Count Value of error count. This
value is reset to 0 after every
reset it is not non-volatile
2 0
GD 16 Set Receive Good Count Value of good count. This
value is reset to 0 after every
reset it is not non-volatile
2 0
HP 17 Set Network number. Each
network uses a different hop
sequence. Seven different network
numbers are available.
Use this parameter to operate
independent networks of
24XStream modules in the
same vicinity.
Range: 0 – 6H
1 0
MK 18 Set Module Address Mask Address mask. Only bits set to
1 are used in the address
comparison. A global address
is an address that has the same
bits set as the address mask.
2 FF
FF
CC 19 Set command sequence character. Number for the command
character.
Range: 20H –7FH
1 2B
VR 20 Firmware version NA 2 NA
BD 21
V4.08
Set Serial Baud Rate Number corresponding to
Serial Port baud rate. Baud
rate doesn’t take affect until
ATCN command is issued. If
the baud command is issued in
binary mode it must be stored
(ATWR) and new baud rate
will take affect after reset.
Range: 1 – 6
1-2400
2-4800
3-9600
4-19200
5-38400
6-57600
1