User's Manual

MaxStream, Inc. 24XStream Wireless Module Manual v2.8
29
Cyclic Sleep Mode Timings
Symbol Description X24-019 X24-009
T
ÄS
Time when module is listening for a valid
header to start receiving data.
100 ms 100 ms
T
SL
Time where the 24XStream is in its low
power cyclic sleep. This time is adjustable
using the SM command.
0.5 seconds
1.0 seconds
2.0 seconds
4.0 seconds
8.0 seconds
(depends on SM)
0.5 seconds
1.0 seconds
2.0 seconds
4.0 seconds
8.0 seconds
(depends on SM)
T
C
Total period between successive pulses of
the module awakening from Sleep Mode.
This value is dependent on the setting of the
SM command.
0.6 seconds
1.1 seconds
2.1 seconds
4.1 seconds
8.1 seconds
(depends on SM)
0.6 seconds
1.1 seconds
2.1 seconds
4.1 seconds
8.1 seconds
(depends on SM)
Timing Diagrams
Pin Timings
Sleep Mode Timings