User's Manual

9XCite Wireless OEM Module – Product Manual v1.0
Table 6. Non-AT Settable Parameters
(Settable using XCite-CTU Software only)
Command
Category
AT Command
Equivalent
Command Description Parameter Range
# Bytes
Returned
Factory
Default
AT
Silence AFTER Sequence - Sets time period of silence after
a command sequence.
Range: 0x00 - 0xFFFF
(milliseconds)
2 0x1F4
BT
Silence BEFORE Sequence – Sets period of silence time
before a command sequence.
Range: 0x00 - 0xFFFF
(milliseconds)
2 0x1F4
CC
Commands Sequence Character –Parameter determines
ASCII command sequence character used to enter AT
Command Mode.
Range: 0x20 – 0x7F 1
0x2B
(plus sign “+”
in ASCII.)
AT Command
Options
CT
Time Out from Command Mode – If no valid commands
have been received within this time period, module returns to
Idle Mode from AT Command Mode.
Range: 0x02 – 0xFFFF
(tenths of a second)
2 0xC8
Networking ID
Assign Module VID – Sets Module VID for creating separate
networks.
Range: 0x00 - 0x3332 1 0x3332
BD
Baud Rate – Sets serial com port’s baud rate (bps) and thus
sets the rate at which serial data enters into the module.
If Com Port Baud rate is set higher than the fixed over-the-air
baud of the module,
may need to be implemented.
Range: 0 – 6
(1200 – 57600 BPS)
1
Set to equal
module’s
over-the-air
Baud rate.
BI
Number of Bits (7 or 8) – Sets number of data bits per
character (Bits between start and stop bits).
Range: 0 – 1
0 = 7 bits
1 = 8
1 1
FL
Software Flow Control – Enables serial software flow control
on the module. (Hardware flow control (
) is always on.)
XON = 0x11, XOFF = 0x13
Range: 0 -1
0 = No software flow control
1 = Use software flow control
1 0
NB
Parity – Sets error-checking parameters for parity systems.
Setting 7 bits (using BI Parameter) and Mark or Space parity
will result in a setting of 7 bits and no parity.
Range: 0 – 4
0 = 8-bit (no parity) or
7-bit (with parity)
1 = 8-bit even parity
2 = 8-bit odd parity
3 = 8-bit mark parity
4 = 8-bit space parity
1 0
RT Mode – Enables Mode.
Range: 0 – 1
0 = None
1 = Handshaking
1 0
Serial
Interfacing
Options
SB Stop Bits – Sets number of stop bits.
Range: 0 – 1
0 = 1 stop bit
1 = 2 stop bits
1 0
HT
Time-to-Beacon – Sets time of inactivity (no serial or RF data
sent or received) before a wake-up beacon is transmitted.
Value should be shorter than time set with ST Command.
Range: 0x00 - 0xFFFF
(tenths of a second)
2
0xFFFF
(no wake-up
beacon sent)
LH
Beacon Transmit Time – Specifies the length of the wake-up
beacon. The length of the beacon should be longer than the
interval if time set using SM Command.
Range: 0x00 - 0xFF
(tenths of a second)
1 1
PW Pin Wake Up – Allow s pin wake up from Cyclic Sleep Mode.
Range: 0 – 1
0 = Disable
1 = Enable
1 0
SM Sleep Mode – Specifies Sleep Mode settings.
Range: 0 – 8
0 = No sleep
1 = Pin Sleep
2 = Serial Port Sleep
3 to 8 = Cyclic intervals
ranging from 0.5 to
16.0 seconds
1 0
Sleep
(Low Power)
ST
Time-to-Sleep – Sets the time of inactivity before entering
Sleep Mode. (This number is only valid with SM Command
Cyclic and Serial Port Sleep settings.)
Range: 0x10x00 - 0xFFFF
(tenths of a second)
2 0x64
© 2003 MaxStream, Inc., Confidential and Proprietary 11