RTS/CMD – Pin 5 (Input)
RTS The RTS signal (request to send) is not implemented for flow control
with the 9XStream modules. All received data (over-the-air) is sent out the
serial port regardless of the RTS signal.
CMD The 9XStream comes with a variety of configurable settings including
power-saving modes and network addressing options. This pin may be used
as a way to manually configure the 9XStream module. When this pin is
asserted (high), incoming serial data (on the DI pin) is interpreted as
commands instead of data. (See the Command Mode section of this manual.)
CONFIG – Pin 9 (Input)
The CONFIG pin (low-asserted) is used to force the module to enter AT
Command Mode. When asserted (low), the serial port baud rate is temporarily
set to match the default baud rate of the 9XStream module. This ensures that
the module will transition into AT Command Mode at a known baud rate.
Upon entering AT Command Mode, all configured parameters, including the
baud rate, remain in their saved state and can be modified as described in the
AT Command Mode section.
IMPORTANT:DO NOT tie the CONFIG pin to an external device as it
may cause problems with module operation. The
CONFIG pin should be tied to an external switch and
used manually to enter AT Command Mode only when
the AT Command Mode cannot be entered under the
normal procedure (see the
AT Command Mode
section).