User's Manual

MaxStream 9XStream™ Wireless OEM Module Manual v2.8
47
Confidential and Proprietary, ©MaxStream, Inc. 2001
Cyclic Sleep Mode Timings
Symbol Description 19200-baud 9600-baud
T
S
Time when module is listening for a valid
header to start receiving data.
100 ms 100 ms
T
SL
Time where the 9XStream is in its low
power cyclic sleep. This time is adjustable
using the SM command.
0.5 seconds
1.0 seconds
2.0 seconds
4.0 seconds
8.0 seconds
(depends on SM)
0.5 seconds
1.0 seconds
2.0 seconds
4.0 seconds
8.0 seconds
(depends on SM)
T
C
Total period between successive pulses of
the module awakening from Sleep Mode.
This value is dependent on the setting of the
SM command.
0.6 seconds
1.1 seconds
2.1 seconds
4.1 seconds
8.1 seconds
(depends on SM)
0.6 seconds
1.1 seconds
2.1 seconds
4.1 seconds
8.1 seconds
(depends on SM)