User's Manual

9XTend™ OEM RF Module - Product Manual v2.x6x
© 2010 Digi Internatonal, Inc. 58
Table 5-03. )Diagnostics
DL
Destination Address Low. Set/Read the
destination address (low 32 bits) of a module.
0 - 0xFFFFFFFF Networking 4
v8020:
0x00000000
v8021:
0x0000FFF
F
(broadcast)
HP
Hopping Channel. Set/Read the channel
hopping sequence. Nodes must have the
same hopping sequence to communicate.
0 - 9 Networking 1 0
ID
Network Address. Set/Read the user
network address. Nodes must have the same
network address to communicate.
0x10 - 0x7FFF Networking 2 0x3332
NH
Network Hops. Set/Read the maximum
number of hops expected in a network route.
This value doesn't limit the number of
hops
allowed, but it is used to calculate timeouts
waiting for network acknowledgements.
0 – 0xFF
[Max number of hops]
Networking 2 7
NN
Network Delay Slots. Set/Read the
maximum random number of network delay
slots before re-broadcasting a network packet.
One network delay slot is approximately
168ms.
0 – 0x10 Networking 2 3
NQ
Network Route Requests. Set/Read the
maximum number of route discovery retries
allowed to find a path to the destination node.
If NQ = 0, a route request will only be sent
once.
0 – 0x0A Networking 2 3
NR
Network Retries. Set/Read the maximum
number of network packet delivery atte
mpts. If
NR > 0, packets sent will request a network
ACK and can be resent up to NR+1 times if no
ACKs are received.
0 – 0xFF Networking 2 1
SH
Source Address High. Set/Read the source
address (high 32 bits) of a module.
0x0013A200
[read-only]
Networking 2 0x0013A200
SL
Source Address Low. Set/Read the source
address (low 32 bits) of a module.
0 - 0xFFFFFFFF
[read-only]
Networking 2 varies
AT
Command
AT Command Name
Parame-
ter
Range
Command
Category
# Bytes
Returned
Factory
Default
AT
Guard Time After. Set/Read required DI pin silent time
after the Command Sequence Characters of the
Command Mode Sequence. The DI silent time is used to
prevent inadvertent entrance into Command Mode.
0 – 0xFFFF
[x 100 msec]
Command Mode
Options
2
0x0A
(1 decimal
second)
BT
Guard Time Before. Set/Read required DI pin silent time
before the Command Sequence Characters of the
Command Mode Sequence. The DI silent time is used to
prevent inadvertent entrance into Command Mode.
0 - 0xFFFF
[x 100 msec]
Command Mode
Options
2 0x0A (10d)
CC
Command Sequence Character. Set/Read the ASCII
character used
between guard times of the AT Command
Mode Sequence (BT + CC + AT)
0x20 - 0x7F
Command Mode
Options
1
0x2B
[ASCII "+"]
CN
Exit Command Mode. Explicitly exit the module from AT
Command Mode. (The same action occurs automatically
when CT expires.)
--
Command Mode
Options
-- --