Automatic DIP Switch Configurations
Each time the module assembly is powered-on, AT commands are sent to the on-board RF module
as dictated by the positions of the DIP switches. DIP switch configurations are sent automatically
during the power-on sequence and affect module parameter values as shown in the table below.
Figure B-04. XTIB-R DIP Switch
Note: The results of SW 2, 5 & 6 ON and SW 5 & 6 ON are the same.
Table B-02. Power-up Options - Commands sent to the module as result of DIP Switch Seings
(SW = DI
P Switch)
Switches Condition Behavior Commands Sent During Power-up
Switches 1 & 2
(Restore Defaults /
Serial Interfacing)
If SW1 & SW2 are
ON (up)
Restore Defaults
ATRE
ATWR
(Restore Defaults)
(Write defaults to non-volatile memory)
If SW1 is ON (up) RS-232 Operation ATCS 0 (RS-232, CTS flow control)
If SW1 is OFF (down)
RS-485/422
Operation
ATCS 3 (RS-485 or RS-422 Operation)
Switches 5 & 6
(TX/RX Modes)
If SW5 & SW6 are
OFF (down)
Multipoint Base
ATMY 0
ATDT FFFF
ATMT 3
(Source Address)
(Destination Address)
(Multi-Transmit option)
If SW5 is OFF (down)
& SW6 is ON (up)
Multipoint Remote
ATAM
ATDT 0
ATMT 0
ATRR A
(Auto-set MY, MY = unique)
(Destination Address)
(Multi-Transmit option)
(Retries)
If SW5 is ON (up) &
SW6 is OFF (down)
Point-to-Point
ATAM
ATDT FFFF
ATMT 3
(Auto-set MY, MY = unique)
(Destination Address)
(Multi-Transmit option)
If SW5 is ON (up) &
SW6 is ON (up)
User Defined
Processor is disabled and AT Commands are not sent to
the module (except for CS command as shown below.)
Table B-03. User Dened Mode (Switches 5 and 6 are ON (up))
Only DIP Switches ON (up) Condition Command Sent During Power-up
SW1, SW5 and SW6
If CS = 0, 1, 2 or 4 CS parameter remains the same
If CS = 3 ATCS 0 (RS-232 operation, CTS flow control)
SW2, SW5 and SW6
If CS = 2 ATCS 2 (GPO1 high)
If CS = 0, 1, 3 or 4 ATCS 3 (RS-485/422 Operation)
SW5 and SW6 only
If CS = 2 ATCS 2 (GPO1 high)
If CS = 0, 1, 3 or 4 ATCS 3 (RS-485/422 Operation)