Maxtor Atlas 10K IV 4-5
4.5 POWER
The Maxtor Atlas 10K IV hard disk drive operates from two supply voltages:
4.5.1 Power Sequencing
You may apply the power in any order or manner, or open either the power or
power return line with no loss of data or damage to the disk drive. However, data
may be lost in the sector being written at the time of power loss. The drive can
withstand transient voltages of +10% to –10% from nominal while powering up
or down.
4.5.2 Power Reset Limits
When powering up, the drive remains reset (inactive) until both rising Voltage
thresholds reset limits are exceeded for 100 ms. When powering down, the drive
resets immediately when either supply voltage drops below the falling voltage
threshold.
Table 4-4 Power Reset Limits
1
MAXTOR ATLAS 10K IV 36.8/73.6/147.1 GB
+12 V +10%, -7%
+5 V ±5%
Allowable ripple and noise for each voltage:
+12 V 800 mV p-p (100 Hz to 8 KHz)
450 mV p-p (8 KHz to 20 MHz)
250 mVp-p (20KHz - 5MHz)
+5 V 250 mV p-p (100 Hz to 20MHz)
DC VOLTAGE THRESHOLD
+5 V V
Threshold
=
4.175V typical
4.0V minimum
4.35V maximum
+12 V V
Threshold
=
9.5V typical
9.0V minimum
10.0V maximum