SCSI Description
Maxtor Atlas 10K IV 5-25
5.11.2.3 Implemented Operating Definition Page (81h)
The Implemented Operating Definition page reflects the current and available operation
definitions as described in Table 5-30 and Table 5-31.
Table 5-30 Implemented Operating Definition Page-Data Format
Table 5-31 Implemented Operating Definition Page-Field Descriptions
Bit
Byte
76543210
0 Peripheral Qualifier
=0
PeripheralDeviceType=0
(Direct Access Device)
1 Page Code (81h)
2 Reserved
3 Page Length = 07h
4 Rsvd Current Definition
5SavImp
=1
Default Definition is SCSI-2 U160 (04h)
6SavImp
=1
Supported-1 Definition is SCSI-3 U320 (06h)
7 * SavImp
=1
Supported-2 Definition is SCSI-3 U160 (05h)
8SavImp
=1
Supported-3 Definition is SCSI-2 U160 (04h)
9SavImp
=1
Supported-4 Definition is SCSI-2 U80 (03h)
10 SavImp
=1
Supported-5 Definition is SCSI-1-CCS (02h)
Field Definition
SavImp
Save Implemented. If = 0, this bit indicates that the
corresponding operation definition cannot be saved.
When = 1, this bet indicates that the corresponding
operating definition can be saved.