User manual

46
Ernitec EDNS V1000 series user manual
www.ernitec.com
V 2.2.082012
<Greater Equal Than>: When the value of a transaction is
greater then or equal to a certain value,
it will be marked as an exception. That
specific value need to be defined in the
following sub-setting <Value>.
<Less Equal Than>: When the value of a transaction is less
than or equal to a certain value, it will be
marked as an exception. That specific
value need to be defined in the following
sub-setting <Value>.
<Inside The Range>: When the value of a transaction is within a
certain range, it will be marked as an
exception. The range need to be defined
in the following sub-setting <Value> and
<Value (Upper Limit)>.
<Outside the Range>: When the value of a transaction is
beyond a certain range, it will be marked
as an exception. The range need to be
defined in the following sub-setting
<Value> and <Value (Upper Limit)>.
NOTE: Transactions will be marked as exceptions in text
database only when: (1) “Exception Strings” and “By
Numerals” are set and (2) “Trigger” is <ON>. The data
stored before hand will not be marked as exceptions.
3.7.4 Input Setup
This item is used to configure the connection settings of the POS
device.
Input Setup
Input Source
Camera Selection
Text Filter
Manual Filter Setup
Input Process
Text Baud Rate
Text Bits
Text Stop
Text Parity
Direct Connected
1
ASCII
ENTER
Canonical
9600
8
1
None