When the engine oil falls below the required
level, the low oil alarm will
come on and the engine will stop automatically. The engine will not
restart until oil is added to the unit to bring it up to the appropriate level.
TO RESET THE GENERATOR
1. Turn off any connected electric devices and stop the engine.
2. Reduce the total wattage of connected electric devices within the
rated output.
3. Use in proper ventilated areas. Maintain at least 3ft of clearance on
all sides for adequate cooling.
4. After checking, restart the engine. (refer to part 3.4 in this manual
for how to start).
Note: The overload alarm may come on for a few
seconds when first using electrical devices that
require a large starting current, such as a
compressor, pump, or refrigerator. This is normal and
not a malfunction.
Note: The overload alarm may come on for a few
seconds when first using electrical devices that
require a large starting current such as a compressor,
pump, or refrigerator. This is normal and not a
malfunction.
Note: When starting the unit, if the low oil alarm
light flickers and the engine will not start, you
will need to add engine oil before attempting to
restart the engine.
Note: Generator should only be operated on a level
surface. DO NOT operate the generator on loose
ground or obvious\ inclines. The low oil shutdown
feature may be prematurely activated in these
22