Product Manual

cases, causing the engine to not start.
12V 8A DC
The 12V 8A DC output is for battery
recharging. Follow instructions in
The owners manual for the battery for
charging procedures.
8A DC Circuit Breaker
The 8A DC circuit breaker turns off
automatically if the current exceeds
8A. If the circuit breaker turns OFF, you
will need to push it in to turn ON
again.
Parallel Output
Two generators can be connected to
increase output. Put parallel wire into the
socket first, then start the two greater
wattage as the normal process. Note:
Put the connection wire into the right
sockets (please refer to 4.4 for how to
connect properly).
Multi-Switch
The multi-switch control fuel valve, choke and
engine switch. When starting the generator,
rotate the multi-switch
counter clockwise from OFF to START
position, then pull recoil cord quickly to start.
After started, rotate the switch to RUN
position. Note: To shut off generator, rotate
multi-switch clockwise to OFF position and
hold until generator turns off.
23