Product Manual

If the engine will not start:
Open the fuel cap to check if the engine has sufficient fuel. Open the oil
cap dispenser and check if the machine has sufficient oil.
Remove the spark plug and turn the engine switch to the ON position
to start the engine. Check to see if there is spark coming from the spark
plug. Replace the spark plug if necessary.
If the engine will still not start then contact Gentech Industries for
technical assistance. The details are on the back page of this operators
manual.
No Electricity/Voltage at the AC Receptacles:
Check if the over current protector is in the ON position. Turn to the ON
position if necessary. If there is still no electricity/voltage after this has been
done it is possible that there is something wrong or damage has been
caused to the AVR (Automatic Voltage Regulator) and or Rotor/Stator.
Do not attempt to do anything further, contact Gentech Industries
immediately for assistance.
PARALLEL CONNECTION WITHIN 2 GENERATORS:
Performance allows you to increase the output by connecting two
generators together by using the parallel connection wires provided.
Note: Make sure generators are powered off and without load
when connecting the parallel wires.
Put the parallel connection wire 1 and 2 into the parallel connection
sockets 3 and 4.
Note: Grounding wire must be properly connected.
37