Owner`s manual

10
PRIMING THE PUMP:
To avoid getting an airlock in your pumps, it is recommended to fill the spa from the filter well.
If an air lock still occurs, follow the instructions below.
1. Run Pump 1 on high speed for 10 seconds. Repeat at least 5 times.
2. If water flow is non-apparent, then shut off the power to the spa.
3. Locate and loosen one of the pump compression fittings on each pump by turning it
counter-clockwise one half of one turn.
4. Allow air to escape from fitting. Once there is a steady water flow tighten the
compression fitting by turning it clockwise until tight.
5. Check once more to make sure that water is flowing from the jets during auto purge.
If so, continue. If still no water flow is coming from the jets, please contact your
Island Spas Dealer.
NOTE: An airlock is not covered under warranty.
CAUTION: Running your spa continuously without water flow will damage your pump(s)
and void your warranty.
NOTE: If the water coming from the jets is surging or pulsating, re-check the water level.
If the water level is lower than halfway up the skimmer opening, add water. If the water
level is correct, check to make sure that the skimmer door is not stuck in the closed
position. If the door is operating properly and the jets are still surging or pulsating, please
call your dealer for assistance.
If your Island Spa comes equipped with a 24 hour circulation system. The return jet for this
system is located in the footwell of the spa. After the spa has finished its purge cycle, verify
that you have adequate waterflow from the return jet. If not, please follow the instructions
below to prime the circulation pump.
PRIMING THE CIRCULATION PUMP:
1. Turn Pump 1 on high speed for 30 seconds.
2. Turn Pump 1 off.
3. Continue until the circulation pump gets water flow.