DANGER RISK OF ELECTRICAL SHOCK
If the GFCI breaker fails to
operate as described, there is
a possibility of an electric shock
if the spa is used. Shut off the
power at the main electrical
service panel until the source of
the problem has been identied
and corrected by a licensed
electrician or qualied spa
technician.
PRIMING THE PUMP
1) Turn off power at electrical service panel.
2) Locate and loosen the pump union by turning it counterclockwise one
half of one turn.
3) Allow air to escape from the tting. When a steady stream of water ows
from the pump union, close it by turning it clockwise until tight.
4) Turn on power at electrical service panel.
5) Check once more to make sure that water is owing from the jets during
auto purge. If so, continue. If no water is coming from your spa jets, please
call your Island Spas dealer for further assistance.
WATER PREPARATION
NOTE: Before putting your new spa into operation, understand that
preparing your new water is an important part of maintenance. Fail-
ure to properly prepare your water can result in substantially de-
creasing the life of the components and may void your warranty in
severe cases. Your Island Spas dealer should have a start-up and
maintenance kit available for you when you purchase your spa.