77
8.3. Remote Control Software Registry Entries
It can also be necessary to intervene in the registry directly in order to enter the MERK II’s
to be controlled. In such a case, proceed as follows:
Open the group
“HKEY_CURRENT_USER\Software\Mayah Communications\Centauri remote” in the
Windows registry
Create a new sub-registry with the name “IP”.
Create three new keys in the sub-registry “IP” with the names
Address
IPControl
Port
If more than 1 MERK II is to be controlled, create an own key for each further MERK II
to be controlled in the group “IP” in addition to “Address” with the name
Address1 (for the first MERK II)
Address2 (for the second MERK II)
.... etc.
Allocate the following values to the keys
Address: IP Address of your momentary MERK II (e.g. “10.0.0.10”)
IPControl: “TRUE” for IP Control and “FALSE” for RS232 Control
Port: '2000'
Port 2000 in the registry has nothing to do with Port 2001 that is entered in the
MERK II under “Network”! A change of one or both of these values results in
communication problems!
Address1: IP Address of the first MERK II to be controlled
Address2: IP Address of the second MERK II to be controlled
.... etc.
Please take into account:
All entries are “case sensitive”. In other words, a strict difference is made between
higher and lower case for all entries.
The IP Address must correspond to the subnetwork mask of your network.
The following entries exist:
a) HKEY_CURRENT_USER\Software\Mayah Communications\Centauri Remote
Baud rate: Baud rate with RS232 Remote Control
Type: Character series
ComPort: Com Port with RS232 Control;
Type: Character series, in capitals
MaxComPorts: Number of Com Ports to be scanned with RS232 Control
Type: DWord, Basis: Hex
SuperUserPassword:
Type: Character series
a) HKEY_CURRENT_USER\Software\Mayah Communications\Centauri Remote\Dialogs:
EnableDetailedLogFile:
Type Character series, in capitals;
TRUE = Detailed Log File
FALSE = simple Log File
EnableDisconnect:
Type Character series, in capitals;
TRUE = Disconnect Dialog
FALSE = no Disconnect Dialog
EnableHardwareStatus:
Type Character series, in capitals;