Take care on 12V DC powered units to observe the correct polarity.
Cables connected to the link unit should be fixed so that any moisture
running down the cable does not is directed away from the link unit. All
glands must be tightened - any unused glands should be fitted with a
blanking plug.
4.3
NETWORK IDENTIFIER
To enable a link unit to be identified from other link units on the network a
unique number is assigned to it using switch SW1
Set the switch as follows
(0 is down, 1 is up)
Identifier
Setting
Identifier
Setting
0
000000
16
010000
1
000001
17
010001
2
000010
18
010010
3
000011
19
010011
4
000100
20
010100
5
000101
21
010101
6
000110
22
010110
7
000111
23
010111
8
001000
24
011000
9
001001
25
01
1001
10
001010
26
011010
11
001011
27
011011
12
001100
28
011100
13
001101
29
011101
14
001110
30
011110
15
001111