User's Manual

NOMAD
- W4-2 SCALES
O
PERATING
I
NSTRUCTIONS
P
AGE
6 of
13
28-Oct-2001
The break duration and job number are defined in NOMAD Central system
setup. Two entries will actually be made by this command - a break entry
timed at the current time and a “picking” entry timed at the current time plus
the break duration.
2.2.5
Free Weigh
To aid verification of the scales and to allow general weighing to be
performed a “Free Weigh” mode is available.
Enter 5. The controller will display the weight on the platform with no
adjustment for tare.
The phrase WEIGHT NOT STABLE” will appear just above the indicated
value whenever the weight varies by more than a preset amount.
To exit this mode press ‘CLR’.
2.2.6
Set Zero
Enter the free weigh mode described above.
Enter ‘6’. The controller will zero the scales platform to the current reading
and save the new zero value in memory.
2.2.7
Power Off
The controller can be put into a low power mode where everything but the
core circuitry is turned off.
Enter7. The display will blank. If using a key it should now be turned
back to the operator position. The controller will not power off completely,
part of it will remain active to maintain the time. The data memory is also
maintained.
To power the scales back on turn the key to the supervisor position or place
a tag against the reader.