A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved
to center silver-colored terminal block screw.
B. Center, silver-colored terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
E. 3/4" (19 mm) UL listed strain relief
Direct Wire,
4
-wire connection:
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cable
C.
3/4"
(19 mm) UL listed strain relief
D. Center, silver-colored terminal block screw
E. Neutral ground wire
F. Neutral wire (white or center wire)
When connecting to the terminal block,
place the hooked end of the wire under the
screw of the terminal block (hook facing
right), squeeze hooked end together and
tighten screw, as shown.
1. Remove center, silver-colored terminal
block screw.
2. Remove neutral ground wire from
external ground conductor screw.
Connect neutral ground wire and place
the hooked end (hook facing right) of the
neutral wire (white or center wire) of
direct wire cable under the center screw
of the terminal block. Squeeze hooked
ends together. Tighten screw.
3. Connect ground wire (green or bare)
of direct wire cable to external ground
conductor screw. Tighten screw.
4. Place the hooked ends of the other
direct wire cable wires under the outer
terminal block screws (hooks facing
right). Squeeze hooked ends together.
Tighten screws.
5. Tighten strain relief screw.
6. Insert tab of terminal block cover into
slot of dryer rear panel. Secure cover
with holddown screw.
7. You have completed your electrical
connection. Now go to “Venting
Requirements.”
IMPORTANT: A 4-wire connection is
required for mobile homes and where local
codes do not permit the use of 3-wire
connections.
Direct wire cable must have 5 ft (1.52 m)
o
f extra length so dryer can be moved
if needed.
Strip 5" (127 mm) of outer covering from
end of cable, leaving bare ground wire at
5" (127 mm). Cut 1
1
2" (38 mm) from 3
remaining wires. Strip insulation back 1"
(25 mm). Shape ends of wires into a hook
shape.
C
B
A
D
E
F
C
B
A
D
E
1
"
(
2
5
m
m
)
5"
(
127
m
m
)
W10135154B EnFrv10.qxd:YB70809-10135134A 4/20/10 2:42 PM Page 18