user manual

10
Maintenance instructions:
Clean lint screen after each cycle.
Removing accumulated lint (disconnect dryer from electricity
a
nd gas supplies before starting this task):
From inside the dryer cabinet:
Lint should be removed every 2 years or more often,
depending on dryer usage. Cleaning should be done
by a qualified person.
F
rom the exhaust vent:
Lint should be removed every 2 years, or more often,
depending on dryer usage.
MAINTENANCE INSTRUCTIONS
I
f dryer does not operate, check the following:
Electric supply is connected.
Circuit breaker is not tripped or fuse is not blown.
Door is closed. Listen closely to hear door switches activate.
Selected cycle button has been pressed firmly and display
s
hows cycle time.
Check that gas supply shutoff valves are set in open position.
If you need assistance:
Contact your authorized Maytag Commercial Laundry distributor
or visit: www.MaytagCommercialLaundry.com. When you call,
you will need the dryer model number and serial number.
Both numbers can be found on the serial-rating plate located
on your appliance.
220-240V~50Hz 1ph 3A max. IP24 Clothes capacity: 9.0 kg max. Sound pressure level, Lpa: 58 dBA
(uncertainty, Kpa: +/–10 dBA) Total mass: 68 kg max.
European Country: CH, CZ, CY, ES, GB, GR, HR,
IE, IT, PT, SI, SK, TR
0.562703 m
3
/hr
30 mbar
37 mbar 30 mbar
28-30 mbar
N/A N/A
N/A
N/A
N/A
7.4 mbar 7.4 mbar
20 mbar
20 mbar
25 mbar
20 mbar
0.562703 m
3
/hr
II
2H3+
II
2H3B/P
II
2H3+
I
2E+
II
2H3B/P
CY, CZ, DK, EE, FI, GR, HU, IT,
NO, RO, SE, SK, TR
CY, CZ, DK, EE, FI, GR, HU, IT,
NO, RO, SE, SK, TR
CH, CZ, CY, ES, GB, GR, HR,
IE, IT, PT, SI, SK, TR
European Gas Category:
Gas Flow Rate:
Supply Pressure (G20):
Factory Adjusted Pressure:
European Country:
European Gas Category:
Butane Supply Pressure (G30):
Adjusted Pressure:
Adjusted Pressure:
Propane Supply Pressure (G31):
Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW
With LP Gas Conversion Kit: Injector size: 1.25 mm Heat input gross: 6.4 kW
With France/Belgium NATURAL GAS conversion kit: Injector size: 1.65 mm Heat input gross: 5.9 kW
FR, BE
European Country:
European Gas Category:
Supply Pressure (G20):
Supply Pressure (G25):
Adjusted Pressure:
NOTE: Conversion kit:From Natural Gas to LP Gas: Whirlpool Part No. W10233219.
Manufacturer: Whirlpool Corporation, 1300 Marion-Agosta Rd., Marion, OH 43302, USA.
Conversion kit:From Natural Gas to Natural Gas - France/Belgium: Whirlpool Part No. W10184947.
EU representatives: Maytag UK Ltd., 2 St. Annes Blvd., Redhill, RH1 1AX, UK
& Bauknecht Hausgeräte GmbH, D-73614 Schorndorf, Germany
TECHNICAL SPECIFICATIONS - GAS DRYER