LOCATION REQUIREMENTS
You will need:
A location allowing for proper exhaust installation.
See “Venting Requirements.”
A separate 15 or 20-amp circuit needed for gas dryers and
30-amp circuit needed for electric dryers.
If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer.
See “Electrical Requirements.”
Floor must support dryer weight of 200 lbs. (90.7 kg).
Also consider weight of companion appliance.
Level oor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), clothes may not
tumble properly and automatic sensor cycles may not
operate correctly.
For garage installation, place dryer at least 18" (460 mm)
above oor.
IMPORTANT: Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures below
45°F (7°C). Lower temperatures may cause dryer not to
shut off at end of automatic sensor cycles, resulting in longer
drying times.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
DRYER DIMENSIONS
INSTALLATION CLEARANCES
For each arrangement, consider allowing more space for ease of
installation and servicing, spacing for companion appliances and
clearances for walls, doors, and oor moldings. Space must be
large enough to allow door to fully open. Add spacing on all sides
of dryer to reduce noise transfer. If a closet door or louvered door
is installed, top and bottom air openings in door are required.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
A. Wide opening side-swing door
B. Wide opening hamper door
*Most installations require a minimum 6" (152 mm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”
53"
(1341 mm)
30"
(762 mm)
43
1
/4"
(1096 mm)
30"
(762 mm)
27"
(685 mm)
1
1
/4"
(32 mm)
40
1
/2"
(1027 mm)
A B