User`s guide
Instructions for Installation (cont'd)
All Installations Standard Vent Kit
Fureaseofassemblytheinstalladonofthevariouskit Installation #1
combinations has been broken into individual sections,
The two steps below are common to all installations. Standard Vent Kit 66001422
Once these have been performed, you need only to refer
o.eeoo.te ,oyou
Installation Using Vent Kits:
1.Standard Vent Kit 66001422 ........................... Page 14
2. Optional Vertical Vent Kit _
with Standard Vent Kit .................................. Page 17
3. Optional Horizontal Vent Kit ........................ Page 21
4. Optional Hotizontal
and Vertical Vent Kits .................................... Page 25 *Eachpartisstampedwitha partnumber
CUTTING THE OPENING THROUGH THE OUTSIDE The opening through the wall should be cut at this time. If it
WALL hasn't been, refer back to that section.
After thoroughly reading the "Locating the New Water
Heater" section of this manual and you have chosen a suit- 1. Lock the elbow to the straight 3" flue pipe. Set this assem-
able water heater installation site, use the chart below to bly in place on the end of the water heater's flue collar.
determine dimensions for the opening in the wall.
Cut a C/4" diameter hole completely through the outside
wall.
2. Mark the flue collar at the slots in the elbow. Using a #22
drill hit, drill holes into the flue collar at the two slots and
WATER HEATER ATTITUDE secure the elbow to the flue collar using the screws provided.
There is a certain amount of variance with regard to the direc- NOTE: Make sure elbow is properly aligned to opening
tion the water heater faces, in the outside wall.
Standing in front of the water heater (gas control facing you),
set the 3" diameter elbow (slotted end) on the flue. This will
give you a better understanding of the relation of the vent __//)I_ "_"_
assembly to the opening in the wafl and more importantly any
possibility of interference of venting and water piping.
The direction of the water heater can now be made. Also con- _ _ _ _ -#
sider the gas control valve to insure installation, lighting, and 0" --__"I_S
maintenance accessibility are retained.