User`s guide
Instructions for Installation (cont'd)
Optional Horizontal Vent Kit
(Cont'd)
3. Using the mbe ofsealant supplied, run an ample amount 6. The standard kit includes a single piece of3" flue and 6"
around the oval flare of the jacket, vent pipe which will not be used in conjunction with the
horizontal kit.
7. Slide the vent collar (to be installed later) over the 6" vent
4. First remove the 3" horizontal extension from the elbow.
elbow.
Starting with the long end (with four securing holes),
place the 6" diameter vent elbow over the 3" diameter
of theelbow. Bend the round end "oval" to fit the flared oval endjacket top. _ "_ /"_"',_
_/_ 8. Place the water heate r at the opening in the wall, at the
predetermined clearance.
5. Making sure the 6" diameter elbow is centered around the _4_ 0_ _111
3" diameter flue, secure the 6" diameter vent pipe using _
four sheet metal screws at the connection of the jacket top.