User`s guide
Installation Instructions (cont'd)
Optional Vertical and
Horizontal Vent Kits (cont'd)
3. Slide the 6" vent telescoping section apart to reveal the 6. Bend the round end of the 6" vent extension oval at the
beads. Using the caulking supplied, fdl the beads, jacket tip and secure it using four sheet metal screws.
4. Uslng the tube of sealant supplied, run an ample amount _._
around the oval flare of the jacket.
7. Place the 3" elbow on the flue extenmon."
NOTE: Make sure elbow is properly aligned to opening
in the outside wall.
Mark the 3" dia. end of the flue extension at the slots in
the elbow. Using a #22 drill bit, drill holes into the flue
extension at the two slots and secure the elbow to the flue
extension using the screws provided
5. Place the if'vent section over the 3" flue section.
Subtract 3/,, from the X dimension used earlier and this --_'_ '7._
gives the length of the 6" vent extension. Slide the 6"
vent extension apart to this dimension and lock it togeth-
er using the two screws supplied.
g_
,. 8. The standard kit includes a single piece of 3" flue and 6"
vent pipe which will not be used in conjunction with the
optional horizontal kit.
0-:-)