Series Ten ELECTRIC WATER HEATER USER’S GUIDE Model Numbers HRX30DERT HRX40DERS HRX40DERT HRX52DERS HRX52DERT HRX66DERT HRX82DERT FOR POTABLE WATER HEATING ONLY GAMA certification applies to all residential electric water heaters with capacities of 20 to 120 Gallons. Input rating of 12 Kw or less at a voltage no greater than 250 V. WARNING READ THE GENERAL SAFETY SECTION BEGINNING ON INSIDE COVER AND THEN THIS ENTIRE MANUAL BEFORE INSTALLING OR OPERATING THIS WATER HEATER.
Safety Instructions WARNING WARNING Improper installation, adjustment, alteration, service or maintenance can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Refer to this manual for assistance consult your local utility or call a Maytag Service Specialist at 1-800-365-0024 for an authorized servicer for further information.
Safety Instructions (cont’d) WARNING WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY: This water heater is equipped for one type voltage only. Check the rating plate near the bottom access panel for the correct voltage. DO NOT use this water heater with any voltage other than the one shown on the model rating plate. Failure to use the correct voltage can cause problems which can result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. If you have any questions or doubts consult your electric company.
Table of Contents Safety Instructions .................................................................................................................................... 2,3 Table of Contents .......................................................................................................................................... 4 Customer Information ........................................................................................................................... 5 Product Specifications ........
Customer Information Thank You for purchasing a Maytag water heater. NEC - National Electrical Code, NFPA 70. This publication is available from your local government or public library or electric company or by writing Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062. Properly installed and maintained, it should give you years of trouble free service.
Product Specifications Model Tank Capacity In Gallons *Element Upper Wattage at 240 Volt Lower Recovery Rate Upper In Gals Per Hr. @ 90°F Rise Lower Diameter Height Maximum Fuse or Circuit Breaker Size **Minimum Wire Size (Gauge) Model Tank Capacity In Gallons *Element Upper Wattage at 240 Volt Lower Recovery Rate Upper In Gals Per Hr.
Accessories and Tools Needed Accessories To simplify the installation Maytag has available the installation parts shown below. You may or may not need all of these accessories depending on your type of installation. Call a Maytag Service Specialist at 1-800-365-0024 for an authorized installer.
Instructions for Installation Removing the Old Water Heater 1 Turn “OFF” electrical supply to the water heater. 5 a. If you have copper piping to the water heater, the two copper water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater. This will avoid cutting off the pipes too short. Additional cuts can be made later if necessary. Disconnect the temperature-pressure relief valve drain line.
Instructions for Installation (cont’d) Locating The New Water Heater CAUTION WATER HEATERS EVENTUALLY LEAK: Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow of water will not cause damage to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor. When such locations cannot be avoided, a suitable drain pan should be installed under the water heater.
Instructions for Installation (cont’d) Water Piping * NOTE: Your water heater is super insulated to minimize heat loss from the tank. Further reduction in heat loss can be accomplished by insulating the hot water lines from the water heater. WARNING HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact.
Instructions for Installation (cont’d) Temperature-Pressure Relief Valve WARNING WARNING At the time of manufacture this water heater was provided with a combination temperature-pressures relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials, as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, and the current edition of ANSI Z21.22 • CSA 4.
Instructions for Installation (cont’d) Filling the Water Heater To fill the water heater with water: 1. Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater. 2. Open the cold water supply valve to the water heater. NOTE: The cold water supply valve must be left open when the water heater is in use. 3. To insure complete filling of the tank, allow air to exit by opening the nearest hot water faucet.
Instructions for Installation (cont’d) Wiring C. Flexible metal conduit or 3 metallic tubing shall be permitted for grounding if all the following conditions are met: 1. The length in any ground return path does not exceed 6 feet. 2. The circuit conductors contained therein are protected by overcurrent devices rated at 20 amperes or less. 3. The conduit or tubing is terminated in fittings approved for grounding.
Instructions for Installation (cont’d) Installation Checklist COLD HOT 1. Whether or not the element conversion is made, the model rating plate must be marked. Using a hard point ink pen, check the appropriate block within the model rating plate, which is located adjacent to the lower access panel. 2. Is the fuse or circuit breaker size correct as shown in the chart in the “Product Specifications” section? HOT COLD CONDUIT 3.
Service and Maintenance Temperature Regulation LOWER THERMOSTAT WITH HIGH LIMIT WARNING HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped.
Service and Maintenance (cont’d) Thermostat Adjustments replaced more often than an anode rod that appears to be intact. Replacement of a depleted anode rod can extend the life of your water heater. Inspection should be conducted by a qualified service technician, and at a minimum should be checked annually after the warranty period. The upper and lower thermostats have been factory set at HOT (approximately 120°F) to reduce the risk of scald injury.
Service and Maintenance (cont’d) Draining Thermostat Removal/Replacement The water heater should be drained if being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary. 1. Turn “OFF” the electrical power to the water heater at the junction box. 1. Before beginning turn “OFF” the electric power supply to the water heater.
Service and Maintenance (cont’d) Thermostat Removal (cont’d) 9. Put plastic terminal cover back in place. 3. Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors. Open the water heater drain valve. Open a nearby hot water faucet which will relieve pressure in the water heater and speed draining. 10. Replace the insulation block and pad to cover the thermostat. 11. Replace access panel, then turn the electric power “ON”.
Service and Maintenance (cont’d) 6. Lift out the tab as shown to unclip the terminal cover from the thermostat. The terminal cover can now be removed from the thermostat. Lift out tab to unclip terminal cover from thermostat. 11. Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater. 12. Open the cold water supply valve to the water heater.
Service and Maintenance (cont’d) Element Cleaning/ Replacement (cont’d) Drain Valve Washer Replacement 16. Replace the terminal cover on the thermostat making sure that the locking tabs on the terminal cover are in place. NOTE: For replacement, use a 17⁄32″ x 13⁄64″ x 1⁄8″ thick washer available at your nearest hardware store. For ordering a replacement washer, refer to the “Repair Parts” section. 1. Before beginning turn “OFF” the electrical power supply to the water heater.
Troubleshooting Start Up Conditions THERMAL EXPANSION Smelly water may be eliminated or reduced in some water heater models by replacing the anode(s) with one of less active material, and then chlorinating the water heater tank and all hot water lines. Call a Maytag Service Specialist at 1-800-365-0024 for an authorized servicer for further information concerning an Anode Replacement Kit #9001453 and this Chlorination Treatment.
Troubleshooting (cont’d) NOT ENOUGH OR NO HOT WATER 1. Before beginning, turn “OFF” electrical power supply to the water heater. 1. In a new installation, the water heater may not be properly connected. Make sure the cold water supply valve is open. Review and check piping installation. Make sure that the cold water line is connected to the cold water inlet to the water heater and the hot water line to the hot water outlet on the water heater. 2.
Troubleshooting (cont’d) Leakage Checkpoints Use this guide to check a “Leaking” water heater. Many suspected “Leakers” are not leaking tanks. Often the source of the water can be found and corrected. CAUTION Read this manual first, then before checking the water heater make sure the electric supply has been turned “OFF”, and never turn the electric supply “ON” before the tank is completely full of water.
Repair Parts List MAYTAG ELECTRIC WATER HEATERS MODEL NUMBERS HRX40DERS 40 GALLON HRX52DERS 50 GALLON NOTE: LOWER ELEMENT and UPPER ELEMENT: These water heaters have 5500 watt lower and upper elements as standard. Order part no. 9000396 replacement element. However, your specific model may be equipped with nonstandard elements. Refer to model rating plate for wattage of non-standard lower and upper elements. Give voltage and element wattage when ordering replacement parts.
Repair Parts List (cont’d) MAYTAG ELECTRIC WATER HEATERS MODEL NUMBERS HRX40DERS 40 GALLON HRX52DERS 50 GALLON KEY NO.
Repair Parts List (cont’d) MAYTAG ELECTRIC WATER HEATERS MODEL NUMBERS HRX30DERT 30 GALLON HRX40DERT 40 GALLON HRX52DERT 50 GALLON HRX66DERT 66 GALLON HRX82DERT 80 GALLON NOTE: LOWER ELEMENT and UPPER ELEMENT: These water heaters have 5500 watt lower and upper elements as standard. Order part no. 9000396 replacement element. However, your specific model may be equipped with nonstandard elements. Refer to model rating plate for wattage of non-standard lower and upper elements.
Repair Parts List (cont’d) MAYTAG ELECTRIC WATER HEATERS MODEL NUMBERS HRX30DERT 30 GALLON HRX40DERT 40 GALLON HRX52DERT 50 GALLON HRX66DERT 66 GALLON HRX82DERT 80 GALLON KEY NO.
Repair Parts List (cont’d) MAYTAG ELECTRIC WATER HEATERS STATE / MAYTAG PART NUMBER CONVERSION KEY STATE MAYTAG 9003501 66001544 9003716 66001709 9003717 66001708 9003719 66001705 9003729 66001733 9003900 66001703 9003909 66001707 9003915 66001704 9003917 66001700 9003919 66001702 9003921 66001744 9003922 66001723 9003929 66001701 9003931 66001706 9003932 66001746 9003934 66001738 9003935 66001739 9003936 66001745 9003965 66001718 9003966 66001719 9003979 66001728 9003997 66001742 9003998 66001743 ETC2X 660
Notes 29
Notes 30
Notes 31
Warranty FULL ONE YEAR WARRANTY For One Year from the date of Original Retail Purchase, any part which fails in normal home use will be repaired or replaced free of charge. If a leak occurs in the Tank, a new water heater of the closest capacity and quality then available, will be replaced free of charge. The warranty of the replacement is the balance of the original water heater’s Warranty.