User's Manual

E
E - 6
INTERIOR
TAKING CARE OF YOUR SMOKE ALARM
Your smoke alarm has been designed and manufactured to be as maintenance-free
as possible. Here are a few simple steps you must perform, in addition to the weekly
tests described in the section “WEEKLY TESTING OF YOUR SMOKE ALARM,” to keep
your unit in good working order.
•Thesmokealarmshouldbevacuumedmonthlyormoreoftenifthereisdust,
dirt or kitchen grease that can accumulate. Use a soft brush or wand attach-
ment and vacuum all slots in the cover and side. FOR YOUR SAFETY, you must
properly clean and maintain your smoke alarm, since a dirty or malfunctioning
unit may fail to alarm or cause unwanted nuisance alarms.
•Iftheunitisdamagedorfailstooperateproperly,andyouhavecheckedthata
good battery is installed correctly, follow the directions in the section "WHERE
TO SEND YOUR SMOKE ALARM IF IT NEEDS SERVICE" for return. FOR
YOUR SAFETY, DO NOT OPEN THE SMOKE ALARM AND TRY TO REPAIR IT
YOURSELF. While smoke alarms are economical devices, they contain preci-
sion electronic components that are precisely calibrated. The manufacturer
must do repairs.
REPLACING THE BATTERY
The smoke alarm will “beep” once a minute for at least 30 days when the battery is
weak. The battery must immediately be replaced with a fresh one.
The battery should also be changed if it does not sound an alarm when tested. TO
REPLACE THE BATTERY:
1. Check if the tamper resist locking pin is installed in the smoke alarm (see “USING
THE TAMPER RESIST LOCKING MECHANISM” section). If so, pull the pin com-
pletely out of the smoke alarm using long-nose pliers.
2. Remove the smoke alarm from the mounting bracket by twisting counterclockwise
3. Replace old battery with a fresh one. If your smoke alarm has a safety light, the
miniature lamp operates on two AA batteries. (See recommended batteries below.)
4. Check that battery connections are secure and the battery is secured in its
compartment
5. Test smoke alarm for proper operation (see “WEEKLY TESTING OF YOUR SMOKE
ALARM” section). The smoke alarm operates on a 9-volt battery. The normal battery
operating life will be one (1) year. The life of some batteries may be less.
6. Firex smoke alarms sold with Ultralife long-life lithium batteries require replacement
approximately every ten (10) years or when the low battery signal sounds.
CAUTION: You should only use the batteries specified here or on the label of
the unit.
For Models A, B, C, E and PB use: Eveready 216, 522 or 1222; Mallory MN1604;
Duracell MN1604; or Ultralife U9VL-J.
For Model E also use AA Heavy Duty for light power. The miniature lamp operates
on two (2) AA batteries. For replacement, use heavy-duty or alkaline AA batteries:
Eveready 1215, E91, or Duracell M15HD, MN1500.
CAUTION: Do not use any type of rechargeable batteries.