Installation guide

ELECTRICAL
CONNECTION
Power
Supply
Cord
Gh
6
Fire
Hazard
Use
a
new
UL
listed
30
amp
power
supply
cord.
Use
a
UL
listed
strain
relief.
Disconnect power
before
making
electrical
connections.
Connect
neutral
wire
(white
or
center
wire)
to
center
terminal
(silver).
Ground
wire
(green
or
bare
wire)
must
be
connected
to
green
ground
connector.
Connect
remaining
2
supply
wires
to
remaining
2
terminals
(gold).
Securely
tighten
all
electrical
connections.
Failure
to
do
so
can
result
in
death,
fire,
or
electrical
shock.
Electrical
Connection
Options
{
1.
Choose
electrical
connection
type
Power
supply
cord
4-wire
receptacle
(NEMA
Type
14-30R):
Go
to
Power
Supply
Cord
Connection.
Power
supply
cord
3-wire
receptacle
(NEMA
Type
10-30R):
Go
to
Power
Supply
Cord
Connection.
4-wire
direct
connection:
Go
to
Direct
Wire
Connection.
3-wire
direct
connection:
Go
to
Direct
Wire
Connection.
NOTE:
If
local
codes
do
not
permit
connection
of
a
cabinet-ground
conductor
to
neutral
wire,
go
to
“Optional
3-wire
connection.”
This
connection
may
be
used
with
either
a
power
supply
cord
or
a
direct
wire
connection.
(9.
Remove
terminal
block
cover
Before
you
start,
disconnect
power.
Remove
hold-down
screw
(D)
and
terminal block
cover
(A).
A.
Terminal
block
cover
B.
External
ground
conductor
screw
C.
Center
terminal
block
screw
D.
Hold-down
screw
E.
Neutral
ground
wire
F.
Hole
below
terminal
block
cover
POWER
SUPPLY
CORD
CONNECTION
Power
Supply
Cord
Strain
Relief
(4
_
Attach
power
supply
cord
strain
relief
Remove
the
screws
from
a
3/4"
(19
mm)
UL
listed
strain
relief
(UL
marking
on
strain
relief).
Put
the
tabs
of
the
two
clamp
sections
(C)
into
the
hole
below
the
terminal
block
opening
(B)
so
that
one
tab
is
pointing
up
(A)
and
the
other
is
pointing
down
(D),
and
hold
in
place.
Tighten
strain
relief
screws
just
enough
to
hold
the
two
clamp
sections
(C)
together.
2.
Attach
power
supply
cord
to
strain
relief
Put
power
supply
cord
through
the
strain
relief.
Be
sure
that
the
wire
insulation
on
the
power
supply
cord
is
inside
the
strain
relief.
The
strain
relief
snould
have
a
tight
fit
with
the
dryer
cabinet
and
be
in
a
horizontal
position.
Do
not
further
tighten
strain
relief
screws
at
this
point.