3. Connect remaining wires
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover
into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to “Venting Requirements.”
2. Connect neutral wire
Connect neutral wire (white or center) (C) of power supply cord
to center terminal block screw (B). Tighten screw.
C
B
Remove center terminal block screw (B).
B
1. Remove center screw
Direct Wire Connection
Unscrew the removable conduit connector (A) and any
screws from a 3/4" (19 mm) UL Listed strain relief. Put the
threaded section of the strain relief (C) through the hole below
the terminal block opening (B). Reaching inside the terminal
block opening, screw the removable conduit connector (A)
onto the strain relief threads.
A
B
C
1. Attach direct wire strain relief
Put direct wire cable through the strain relief. The strain relief
should have a tight  t with the dryer cabinet and be in a
horizontal position. Tighten strain relief screw against the direct
wire cable.
2. Attach direct wire cable to strain relief
Direct wire strain relief
3-wire direct connection:
Go to “3-Wire Direct Connection” on page 11.
4-wire direct connection:
Go to “4-Wire Direct Connection” on page 11.
If your wiring looks like this: