Installation guide

INSTALLATION
REQUIREMENTS
Tools
and
Parts
Gather
the
required
tools
and
parts
before
starting
installation.
Read
and
follow
the
instructions
provided
with
any
tools
listed
here.
Tools
needed
Phillips
screwdriver
Flat-blade
screwdriver
Measuring
tape
Drill
(for
wall
cabinet
installations)
1"
(2.5
cm)
drill
bit
(for
wall
cabinet
installations)
Level
Parts
needed
m
CSA
approved
wire
connectors
Parts
supplied
m
Two
4x25
mm
self-tapping
screws
mw
CSA
approved
conduit
connector
Check
local
codes.
Check
existing
electrical
supply.
See
“Electrical
Requirements.”
It
is
recommended
that
all
electrical
connections
be
made
by
a
licensed,
qualified
electrical
installer.
Yayo
gh
ge,
Eg,
gomez
a
ge
apr
ye
Inge
LOCaiion
Requiremenis
IMPORTANT:
Observe
all
governing
codes
and
ordinances.
m
Cabinet
opening
dimensions
that
are
shown
must
be
used.
Given
dimensions
provide
minimum
clearance
with
oven.
m
Recessed
installation
area
must
provide
complete
enclosure
around
the
recessed
portion
of
the
oven.
m
Grounded
electrical
supply
is
required.
See
“Electrical
Requirements”
section.
mg
Electrical
supply
junction
box
should
be
located
3”
(7.6
cm)
maximum
below
the
support
surface
when
the
oven
is
installed
in
a
wall
cabinet.
A
1"
(2.5
cm)
minimum
diameter
hole
should
have
been
drilled
in
the
right
rear
or
left
rear
corner
of
the
support
surface
to
pass
the
appliance
cable
through
to
the
junction
box.
NOTE:
For
undercounter
installation,
it
is
recommended
that
the
junction
box
be
located
in
the
adjacent
right
or
left
cabinet.
If
you
are
installing
the
junction
box
on
rear wall
behind
oven,
the
junction
box
must
be
recessed
and
located
in
the
upper
or
lower
right
or
left
corner
of
the
cabinet
to
allow
the
oven
to
fit
into
the
cabinet
opening.
m
Oven
support
surface
must
be
solid,
level
and
flush
with
bottom
of
cabinet
cutout.
Floor
must
be
able
to
support
an
oven
weight
of
140
Ibs
(63.5
kg).
IMPORTANT:
To
avoid
damage
to
your
cabinets,
check
with
your
builder
or
cabinet
supplier
to
make
sure
that
the
materials
used
will
not
discolor,
delaminate
or
sustain
other
damage.
This
oven
has
been
designed
in
accordance
with
the
requirements
of
CSA
International
and
complies
with
the
maximum
allowable
wood
cabinet
temperatures
of
194°F
(90°C).
Undercounter
Installation
(with
cooktop
installed
above):
Ovens
approved
for
this
type
of
installation
have
an
approval
label
located
on
the
top
of
the
oven. Refer
to
undercounter
installation
instructions
for
cutout
dimensions
and
approved
oven
cooktop
combinations
(a
separate
sheet).
Product
Dimensions
A.
21%"
(54.5
cm)
B.%"
(20
mm)
C.
23/2"
(59.5
cm)
D.
23%"
(59.5
cm)
E.
22%"
(57.2
cm)
F.
21%"
(53.8
cm)
G.
21
48"
(53.7
cm)
Cabinet
Dimensions
IMPORTANT:
The
cabinet
should
be
configured
with
openings
as
shown
in
the
following
illustrations
to
allow
the
cooling
system
to
work
properly.
Suggested
dimenions
of
the
openings
are
shown.
Arrows
show
the
air
circulation
needed
for
proper
cooling
of
the
oven
during
operation.
Undercounter
A.
1
%6"
(3.0
cm)
maximum
B.
1958"
(50.0
cm)
minimum
C.
21%"
(55.0
cm)
minimum
D.
22"
(56.0
cm)
minimum
E.
23
38"
(60.0
cm)
minimum