Instructions / Assembly

W10607131 B
Installation Instructions
for W10606694 L.P. (Propane and Butane)
Gas Conversion Kit
Parts included in Kit:
1 Instruction Sheet
1 Blocking Pin
1
1
1 Label, Rating Plate Conversion (English)
1 Label, Rating Plate Conversion (French)
1 Label, Conversion Record (English)
1 Label, Conversion Record (French)
1 Label, Burner Baseplate (English/French)
Converting 20,000 BTU/hr Gas Burners from Natural Gas
to Liquefied Petroleum (Bottled Gas)
NOTE:
representative of a company who is experienced or trained
in servicing gas equipment and is familiar with necessary
precautions.
IMPORTANT: The LP Conversion Kit you received is an
approved kit for converting your gas dryer from natural to LP
propane or butane gas. The kit no. shown on the Burner Data
Label located on the Burner Base may not match the kit you
receive due to kit consolidation.
NOTE: Read these instructions before proceeding.
Canada Only
THIS CONVERSION KIT SHALL BE CARRIED OUT IN
ACCORDANCE WITH THE REQUIREMENTS OF THE
PROVINCIAL AUTHORITIES HAVING JURISDICTION AND
IN ACCORDANCE WITH THE REQUIREMENTS OF THE
CAN-B49.1 AND CAN1-B149.2 INSTALLATION CODE.
Warning:
service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements of
the authority having jurisdiction. The information in these
explosion or to prevent property damage, personal injury,
proper installation of this kit. The installation is not proper
and complete until the operation of the converted appliance
supplied with this kit.
This dryer has been manufactured for use with Natural Gas.
Installation of this conversion kit converts the dryer for use with
L.P. gas with supply pressure between 8" (203 mm) and
13" (330 mm) water column. If this dryer is converted for use
with L.P. gas by means of this kit, the input rating will be 20,000
BTU’s per hour, for altitudes up to 10,000 feet (3,048 m). For
agency for derating instructions.
READ THOROUGHLY AND FOLLOW STEPS
1. Unplug dryer or disconnect power.
2. Turn off gas supply using the shut-off valve that supplies
the dryer.
3.
Fill out information on the appropriate Conversion Record
Label (English or French) and apply in a conspicuous
location adjacent to model and serial tag located in the
door well. Go to section 1, 2, or 3 depending on your model.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Section 1 - Clothes Dryer with A Full-Front Panel & Front Mounted Console .... page 2
Section 2 - Dryers with Toe Panel ........................................................................... page 5
Section 3 - Dryers with A Full-Front Panel & Rear Mounted Console ................. page 5
Orifice, Burner-Butane No. 55
Orifice, Burner-Butane No. .049