Installation Instructions
6
Side view:
Front view:
DRYER DIMENSIONS
*Approx. measurement
Maytag
®
Models
Whirlpool
®
, Amana, and Inglis Models
*Approx. measurement
38/4" Minimum
(984mm)
39" Maximum
(990mm)
Back view:
*Approx. measurement
NOTE: Most installations require a minimum of 5"(127mm)
clearance behind dryer for exhaust vent with elbow.
See “Venting Requirements.”
Installation Clearances
For each arrangement, consider allowing more space for ease of
installation and servicing, spacing for companion appliances, and
clearances for walls, doors, and oor moldings. Space must be
large enough to allow door to fully open. Add spacing on all sides
of dryer to reduce noise transfer. If a closet door or louvered door
is installed, top and bottom air openings in door are required.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
Installation spacing for recessed area or closet
installation
All dimensions show recommended and minimum spacing
allowed.
■
Additional spacing should be considered for ease of
installation and servicing.
■
Additional clearances might be required for wall, door, oor
moldings, dryer venting, and gas line.
■
Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
■
For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
■
Companion appliance spacing should also be considered.
Water inlet
(Steam Models Only)
Vent
Gas