Specification

PRODUCT MODEL NUMBERS
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Because Whirlpool Corporation includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Page 1 of 2
Ref. W10694025
05/20/2016
MGR8800F
30" (76.2 cm) Freestanding Gas Range
GAS SUPPLY REQUIREMENTS
Type of Gas:
Natural Gas:
This range is factory set for use with Natural gas. See “Gas
Conversions” section. The model/serial/rating plate is located on
the oven frame behind the top right-hand side of the oven door has
information on the types of gas that can be used. If the types of gas
listed do not include the type of gas available, check with the local gas
supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial/rating plate for use with a different gas
without consulting the serving gas supplier. See “Gas Conversions”
section.
Gas Supply Line
Provide a gas supply line if
3
/
4
" (1.9 cm) rigid pipe to the range
location. A smaller pipe on longer runs may result in insuffient
gas supply. With LP gas, piping or tubing size can be
1
/
2
" (1.3 cm)
minimum. Usually, LP gas suppliers deteremine the size and materials
used in the system. NOTE: Pipe-joint compounds that resist the
action of LP gas must be used. Do not use TEFLON tape.
Flexible metal appliance connector:
If local codes permit, a new CSA design-certified, 4 to 5 ft
(122 to 152.4 cm) long,
1
/
2
" (1.3 cm) or
3
/
4
" (1.9 cm) I.D. (inside
diameter), flexible metal appliance connector may be used for
connecting range to the gas supply line.
A
1
/
2
" (1.3 cm) male pipe thread is needed for connection to the female
pipe threads of the inlet to the appliance pressure regulator.
Do not kink or damage the flexible metal tubing when moving the
range.
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This
valve should be located in the same room but external to the range
opening, such as an adjacent cabinet. It should be in a location that
allows ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the range.
A. Gas supply line
B. Shutoff valve “open” position
C. To range
®
TEFLON is a registered trademark of Chemours.
PRODUCT DIMENSIONS
A. 27
7
/
8
" (70.8 cm) max. depth with handle
B. 36" (91.4 cm) cooktop height (max.)
with leveling legs screwed in all the way*
C. 47
1
/
8
" (119.7 cm) overall height (max.)
with leveling legs screwed in all the way*
D. 29
7
/
8
" (75.9 cm) width
E. 25
7
/
16
" (64.6 cm) depth. Back of range
to front of cooktop**
F. Model/serial/rating plate (located on the oven
frame behind the top right-hand side of the oven door)
* Model/serial/rating plates may be rotated up from behind the control
panel for viewing front the front of the range.
** Front door and drawer may extend farther forward, depending on
styling.
ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required.
A time-delay fuse or curcuit breaker is also recommended. It is
recommended that a separate circuit serving only this range be provided.
A
B
C
F
A
B
C
D
E

Summary of content (2 pages)