Installation Instruction

9
3. Use a 15/16" (2.4 cm) combination wrench and an adjustable
wrench to attach the exible connector to the adapters.
IMPORTANT: All connections must be wrench-tightened. Do
not make connections to the gas regulator too tight. Making
the connections too tight may crack the regulator and cause
a gas leak. Do not allow the regulator to turn when tightening
ttings.
Complete Connection
1. Check that the gas pressure regulator shutoff valve is in the
“on” position.
2. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
3. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear, a
leak is indicated. Correct any leak found.
4. Remove cooktop burner caps and grates from parts
package. Place the burner bases as indicated by the
following illustration for your model:
For Models KFGG500E:
For Models MGR8800F and MGR8800H:
5. Burner caps should be level when properly positioned. If
burner caps are not properly positioned, surface burners will
not light. Place burner grates over burners and caps.
6. Place the burner caps on the appropriate burner bases.
IMPORTANT: The bottom of the small and medium caps are
different. Do not put the wrong size burner cap on the burner
base.
7. Plug into a grounded 3 prong outlet.
8. Slide range into nal location, making sure the rear leveling
leg slides into the slot of the anti-tip bracket.
A
B
C
D
E
FG
H
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have 1/2"
(1.3 cm) male pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F. 1/2" (1.3 cm) or 3/4" (1.9 cm)
gas pipe
G. Use pipe-joint compound.
H. Adapter
A
A. Gas pressure regulator shutoff valve
shown in the “on” position
A
D
C
EB
A. Medium (Semi Rapid)
B. Large (Ultra Rapid)
C. Medium (Semi Rapid) D. Small (Auxiliary)
E. Large (Ultra Rapid)
A D
C
EB
A. Medium (Semi Rapid)
B. Large (Ultra Rapid)
C. Oval (OV) D. Small (Auxiliary)
E. Large (Ultra Rapid)
C
A
B
A. Burner base
B. Burner cap
C. Burner grate
A. Closed valve
B. Open valve
Small (Auxiliary)
Medium (Semi Rapid)
Large (Ultra Rapid)
AUX
SR
UR
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING