Installation Guide
13
Recommended Vent Length
A 3
1
⁄
4
" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round 
vent should be used.
The total length of the vent system including straight vent, 
elbow(s), transitions and wall or roof caps must not exceed 
the equivalent of 140 ft (42.7 m) for either type of vent. See 
the “Recommended Standard Fittings” section for equivalent 
lengths.
For best performance, use no more than three 90° elbows.
To calculate the length of the system you need, add the 
equivalent lengths of each vent piece used in the system.
See the following examples:
3
1
⁄
4
" x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) 
total
6" (15.2 cm) vent system = 73 ft (22.2 m) total
If the existing vent is round, a rectangular to round transition 
piece must be used. In addition, a rectangular 3" (7.6 cm) 
extension vent between the damper assembly and rectangular to 
round transition piece must be installed to keep the damper from 
sticking.
A B
C
6 ft (1.8 m)
2 ft
(0.6 m)
A. One 3
1
⁄
4
" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)
B. 1 wall cap = 40 ft (12.2 m)
C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
A B
C D
6 ft (1.8 m)
2 ft
(0.6 m)
A. Two 90° elbows = 20 ft (6.1 m)
B. 1 wall cap = 40 ft (12.2 m)
C. 1 rectangular-to-round transition piece = 5 ft (1.5 m)