11. Remove two (2) 1/4" (6 mm) screws holding dispenser housing to
bezel.
12. Using pliers, disconnect fabric softener hose clamp as shown in below
figure.
13. Using pliers, disconnect two (2) hose clamps at bulk dispenser pump
as shown in below figure.
14. Bulk dispenser housing can now be removed and replaced.
15. To remove reed switch only use a small screwdriver to push in on tabs
and slide to the right.
Removing the Tub Ring, Impeller, and Basket
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Lifting the Top Panel
NOTE: There is a new catch at the front left and right of the top panel that needs
to be disengaged to remove top panel.
1. Unplug washer or disconnect power.
2. Turn off water supply to washer.
3. Disconnect hot and cold inlet water hoses.
4. Tape lid down.
5. Remove three (3) 1/4" (6 mm) hex-head mounting screws from the rear
of the console as indicated. Remove harness cover and set aside.
6. To remove the top panel, a tool such as a stiff putty knife must be used
to bend up the hook so the tab (Figure B) will be freed from the slot.
This allows the top to be slid forward and removed. It is important to
insert the putty knife behind the hook (Figure A), not in front of it. Please
use care when using these tools to avoid damaging the finish on the
consumers unit.
NOTE: Wrap a tape around a putty knife or add a tape to chassis to
avoid the damage when pushing the knife down.
B
A
A. Fabric Softener Hose Clamp
B. Clamps at Bulk Dispenser Pump (2)
A
C
B
Figure A
A. Putty Knife
B. Hook
C. Slot