TECHNICAL SPECIFICATIONS Model PGC2T (C and L) Series SmartStart ® M1200 Product Line Two Stage, Fixed Speed ECM, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces 95.
The high efficiency gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States. 2 Features and Benefits - i SEER — Energy efficient brushless DC (ECM) motor gives up to 1 SEER point efficiency gain in cooling. - 100% fired and tested — All units and each component are tested on the manufacturing line.
GAS FURNACE COMPONENTS LOCATION OF FURNACE COMPONENTS UPFLOW / HORIZONTAL FURNACE (*TC SERIES) Flame Sensor Finish Flange Roll-Out Switch Burner Assembly Igniter Pressure Switches (Inducer) AIR FLOW Main Air Limit Switch Gas Valve Furnace Control Board Inducer Limit Switch Pressure Switches (Condensate) Transformer Inducer Assembly Blower Door Switch Motor Control Box Motor Choke (C & D cabinets only) 1 2 34 5678 Motor Control Board Blower Assembly Upflow/Horizontal Gas Furnace Components DO
DIMENSIONS *TC 95.1% Upflow/Horizontal Furnace TOP VIEW Dim. “A” ‘B’ Cabinet 17 1/2 ‘C’ Cabinet 21 ‘D’ Cabinet 24 1/2 NOTES: Dimensions shown in inches. Dim. “B” 15 7/8 19 3/8 22 7/8 Dim.
BLOWER PERFORMANCE PGC2TC/TL PGC2TC/TL - 95.1% AFUE, Two Stage Gas Furnace Model Number & Heating Input (Btuh) *TC / TL - 060D - 24B (60,000) *TC / TL - 80D - 35C (80,000) External Static Pressure (in.W.C.) Motor Switch Settings (0 = OFF, 1 = ON) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.
BLOWER PERFORMANCE PGC2TC/TL CONTINUED PGC2TC/TL - 95.1% AFUE, Two Stage Gas Furnace Model Number & Heating Input (Btuh) *TC / TL - 100D - 35C (100,000) *TC / TL - 120D - 45D (120,000) External Static Pressure (in.W.C.) Motor Switch Settings (0 = OFF, 1 = ON) 0.1 0.2 0.3 0.4 0.5 0.6 0.
IDENTIFICATION CODE Maytag Gas Compact PGC 2 T C 090 C 23 B Cabinet Width B = 17.50 C = 21.00 D = 24.50 Design Series S = Single Stage T = Two Stage Cooling Airflow 23 = 2-3 Tons 24 = 2-4 Tons 35 = 3-5 Tons 45 = 4-5 Tons C = Standard V = VSB D = 90+% AFUE Low NOx A = 80% Upflow/Horizontal C = 92.1% / 95.1% Upflow/Horizontal K = 80% Downflow L = 92.1% / 95.
ACCESSORIES PGC2T (C, L) KITS Description SKU Fixed speed -to- variable speed 904880 2" Concentric vent kit 904177 3" Concentric vent kit 904176 "A" Cabinet downflow sub base kit 902974 "B", "C", "D" Cabinet downflow sub base kit 904911 2" Side wall vent kit 904617 3" Side wall vent kit 904347 U.S. LP Conversion kit (0 to 10,000 ft.) 904914 Canada LP Conversion kit (0 to 4,500 ft.