TECHNICAL SPECIFICATIONS Model PSH4BG Series M1200 Product Line R-410A Ultra High Efficiency Heat Pump Up to 19.
• M 1200 – 12 YEAR ALL PARTS LIMITED WARRANTY • M 1200 WITH UPGRADED WARRANTY PACKAGE 12 YEAR ALL PARTS & LABOR LIMITED WARRANTY • B oth the standard and upgraded limited warranty packages offer a 12 Year Dependability Promise to replace the entire unit, if the unit’s major component (compressor) fails within the first 12 years of operation, to the original owner. All split system products must be installed with a matched indoor air handler or indoor coil to qualify.
DIMENSIONS/OUTDOOR SECTION Up to 19 SEER — Ultra High Efficiency PSH4BG 024K 036K 048K 060K H 37 41 41 45 W 31 1/4 31 1/4 31 1/4 31 1/4 D 31 1/4 31 1/4 31 1/4 31 1/4 Air Discharge Allow Adequate Clearance for Airflow W D H IDENTIFICATION CODE P S P - Premier S - Split H - Heat Pump H 4 B G 036 K Product Identifier Generation 1, 2, 3, etc. BG = Braze 17-19.
PHYSICAL AND ELECTRICAL SPECIFICATIONS/OUTDOOR UNITS Unit Size: 024K Volts-Cycles-Phase (1) Total Amps Delay Fuse Max. (2) Min. Circuit Ampacity Electrical Data Coil Fan Motor Condenser Data Compressor Data Service Valves Installation Refrigerant Vapor Line Size (All liquid lines 3/8” OD) Area (ft2) Rows - FPI Tube Diam Type Amps HP RLA LRA Liquid Side Vapor Side 0 - 24 ft. equiv. 25 - 39 ft. equiv. 40 - 75 ft. equiv. (4) 75 - 100 ft. equiv. (4) 13.1 25 15.8 20.3 1-18 3/8” OD 2.6 1/3 10.
SYSTEM CAPACITIES AND MATCHES Up to 19 SEER — Ultra High Efficiency — Single Phase Model Number Coil Model Number PSH4BG024K PSH4BG024K PSH4BG024K PSH4BG024K PSH4BG024K PSH4BG024K PSH4BG024K PSH4BG024K PSH4BG024K PSH4BG036K PSH4BG036K PSH4BG036K PSH4BG036K PSH4BG036K PSH4BG036K PSH4BG036K PSH4BG036K PSH4BG036K PSH4BG036K PSH4BG036K PSH4BG036K PSH4BG036K PSH4BG036K PSH4BG036K PSH4BG048K PSH4BG048K PSH4BG048K PSH4BG048K PSH4BG048K PSH4BG048K PSH4BG048K PSH4BG048K PSH4BG048K PSH4BG060K PSH4BG060K PSH4BG060K
COOLING EXPANDED RATINGS 2 Ton Split Heat Pump w/ Air Handler First Stage (Low Speed C1) Cooling Matched with B6VMAX24K-B-Air Handler Outdoor Temperature: 65°F Blower Indoor Indoor T.C. S.C. cfm Tdb Twb 80 62 12.5 12.1 80 67 13.9 9.8 450 80 72 15.4 7.7 75 62 12.6 10.2 80 62 13.4 13.2 80 67 14.3 10.9 550 80 72 15.8 8.3 75 62 13.1 11.2 80 62 14.3 14.2 80 67 14.8 11.9 650 80 72 16.2 9.0 75 62 13.6 12.3 75°F 85°F 95°F 105°F 115°F kW T.C. S.C. kW T.C. S.C. kW T.C. S.C. kW T.C. S.C. kW T.C. 0.4 0.4 0.
COOLING EXPANDED RATINGS (CONTINUED) 3 Ton Split Heat Pump w/ Air Handler First Stage (Low Speed C1) Cooling Matched with B6VMAX36K-B Air Handler Outdoor Temperature: Blower cfm Indoor Indoor Tdb Twb 65°F 75°F T.C. S.C. kW T.C. 85°F S.C. kW T.C. 95°F S.C. kW T.C. 105°F S.C. kW T.C. 115°F S.C. kW T.C. 125°F S.C. kW T.C. S.C. kW 700 80 80 80 75 62 67 72 62 20.0 22.3 24.4 20.2 19.1 16.0 12.4 15.4 0.7 19.2 18.5 0.8 18.3 17.9 1.0 17.3 17.0 1.1 16.2 16.0 1.3 14.9 14.9 1.5 13.6 13.6 1.
COOLING EXPANDED RATINGS (CONTINUED) 4 Ton Split Heat Pump w/ Air Handler First Stage (Low Speed C1) Cooling Matched with B6VMAX48K-C Air Handler Outdoor Temperature: 65°F Blower Indoor Indoor T.C. cfm Tdb Twb 750 900 1050 80 80 80 75 80 80 80 75 80 80 80 75 62 67 72 62 62 67 72 62 62 67 72 62 25.7 29.7 32.0 25.7 26.8 30.6 32.8 26.8 28.0 31.5 33.6 26.8 75°F 85°F 95°F 105°F 115°F 125°F S.C. kW T.C. S.C. kW T.C. S.C. kW T.C. S.C. kW T.C. S.C. kW T.C. S.C. kW T.C. S.C. kW 22.4 19.
COOLING EXPANDED RATINGS (CONTINUED) 5 Ton Split Heat Pump w/ Air Handler First Stage (Low Speed C1) Cooling Matched with B6VMAX60K-C Air Handler Outdoor Temperature: Blower Indoor Indoor cfm Tdb Twb 850 1000 1150 65°F T.C. S.C. 75°F kW T.C. S.C. 85°F kW T.C. S.C. 95°F kW T.C. S.C. 105°F kW T.C. S.C. 115°F kW T.C. S.C. 125°F kW T.C. S.C. kW 80 62 27.6 25.2 1.0 26.1 24.6 1.2 24.6 23.9 1.4 23.1 23.1 1.7 21.6 21.6 1.9 20.1 20.1 2.1 18.7 18.7 2.4 80 67 31.0 21.3 1.
COOLING EXPANDED RATINGS with COIL 2 Ton Split Heat Pump w/ G7 furnace & B Coils First Stage (Low Speed C1) Cooling FT4BG024 or PSH4BG024 Heat Pump matched with C6BH-X26C-B or C6BA-F42(C,U)-B+TXV-X2.0 Coil Outdoor Temperature: Blower cfm 450 550 650 Indoor Tdb Indoor Twb 65°F T.C. S.C. 75°F kW T.C. S.C. 85°F kW T.C. S.C. 95°F kW T.C. S.C. 105°F kW T.C. S.C. 115°F kW T.C. S.C. 125°F kW T.C. S.C. kW 80 62 12.5 12.1 0.4 11.8 11.7 0.5 11.1 11.1 0.6 10.5 10.5 0.8 9.9 9.
COOLING EXPANDED RATINGS with COIL (CONTINUED) 3 Ton Split Heat Pump w/ G7 Furnace + C Coils First Stage (Low Speed C1) Cooling FT4BG036 or PSH4BG036 Heat Pump matched with C6BH-X36C-C or C6BA-F48(C,U)-C+TXV-X3.0 Coil Outdoor Temperature: Blower cfm 700 800 900 Indoor Tdb Indoor Twb 65°F T.C. S.C. 75°F kW T.C. S.C. 85°F kW T.C. S.C. 95°F kW T.C. S.C. 105°F kW T.C. S.C. 115°F kW T.C. S.C. 125°F kW T.C. S.C. kW 80 62 19.9 19.1 0.7 19.1 18.5 0.8 18.2 17.9 1.0 17.2 17.
COOLING EXPANDED RATINGS with COIL (CONTINUED) 4 Ton Split Heat Pump w/ G7 Furnace + C Coils First Stage (Low Speed C1) Cooling FT4BG048 or PSH4BG048 Heat Pump matched with C6BH-X48C-C or C6BA-F60(C,U)-C+TXV-X4.0 Coil Outdoor Temperature: Blower cfm 750 900 1050 65°F 75°F 85°F 95°F 105°F 115°F 125°F Indoor Tdb Indoor Twb T.C. S.C. kW T.C. S.C. kW T.C. S.C. kW T.C. S.C. kW T.C. S.C. kW T.C. S.C. kW T.C. S.C. kW 80 80 62 67 25.6 29.6 22.4 19.7 1.0 1.0 24.3 28.9 21.
COOLING EXPANDED RATINGS with COIL (CONTINUED) 5 Ton Split Heat Pump w/ G7 + D coils First Stage (Low Speed C1) Cooling FT4BG060 or PSH4BG060 Heat Pump matched with C6BH-X60C-D or C6BA-F60(C,U)-D+TXV-X5.0 Coil Outdoor Temperature: Blower cfm 65°F Indoor Indoor Twb T.C. Tdb 75°F 85°F 95°F 105°F 115°F 125°F S.C. kW T.C. S.C. kW T.C. S.C. kW T.C. S.C. kW T.C. S.C. kW T.C. S.C. kW T.C. S.C. kW 850 80 80 80 75 62 67 72 62 27.6 31.0 34.4 28.2 25.2 21.3 16.9 21.8 1.0 1.0 0.9 1.
HEATING EXPANDED RATINGS WITH AIR HANDLER 2 Ton Split Heat Pump with Air Handler First Stage (Low Speed H1) Heating Matched with B6VMAX24K-B-Air Handler Outdoor Temperature: Blower cfm (nominal) 450 550 650 E.D.B 0°F 10° 17° 20° 30° 40° 47° 50° 60° T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW 60 4.4 2.3 0.6 5.5 2.8 0.6 6.3 3.1 0.6 6.7 3.3 0.6 8.0 3.8 0.6 9.3 4.4 0.6 10.3 4.8 0.6 10.8 5.0 0.6 12.3 5.7 0.6 70 4.0 1.9 0.6 5.
HEATING EXPANDED RATINGS WITH AIR HANDLER (Continued) 3 Ton Split Heat Pump with Air Handler First Stage (Low Speed H1) Heating Matched with B6VMAX36K-B Air Handler Outdoor Temperature: Blower cfm (nominal) 700 800 900 E.D.B 0°F 10° 17° 20° 30° 40° 47° 50° 60° T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW 60 7.3 2.7 0.8 9.0 3.1 0.8 10.3 3.5 0.9 10.9 3.6 0.9 12.9 4.2 0.9 15.2 4.9 0.9 16.9 5.3 0.9 17.6 5.6 0.9 20.2 6.4 0.9 70 6.
HEATING EXPANDED RATINGS WITH AIR HANDLER (Continued) 4 Ton Split Heat Pump with Air Handler First Stage (Low Speed H1) Heating Matched with B6VMAX48K-C Air Handler Outdoor Temperature: Blower cfm 0°F 10° 17° Indoor T.C. COP kW T.C. COP kW T.C. COP kW T.C. Tdb 20° 30° 40° 47° 50° 60° COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW 750 60 70 80 7.8 6.7 5.6 2.8 0.8 9.2 2.2 0.9 8.2 1.7 0.9 7.3 3.1 0.9 10.3 3.3 0.9 10.8 2.6 0.9 9.4 2.8 1.0 9.9 2.1 1.0 8.5 2.3 1.1 9.1 3.5 2.
HEATING EXPANDED RATINGS WITH AIR HANDLER (Continued) 5 Ton Split Heat Pump with Air Handler First Stage (Low Speed H1) Heating Matched with B6VMAX60K-C Air Handler Outdoor 0°F 10° 17° 20° 30° 40° 47° 50° 60° Temperature: Blower Indoor T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW cfm Tdb 850 1000 1150 60 6.4 2.5 0.7 7.8 2.9 0.8 8.8 3.2 0.8 9.3 3.4 0.8 10.9 3.9 0.8 12.6 4.4 0.8 13.9 4.8 0.8 14.4 5.0 0.8 16.4 5.6 0.8 70 6.0 2.2 0.8 7.
HEATING EXPANDED RATINGS WITH Coils (Continued) First Stage (Low Speed H1) Heating FT4BG024 or PSH4BG024 Heat Pump matched with C6BH-X26C-B or C6BA-F42(C,U)-B+TXV-X2.0 Coil Outdoor Temperature: Blower cfm 450 550 650 0°F 10° 17° 20° 30° 40° 47° 50° 60° Indoor T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW Tdb 60 4.5 2.3 0.6 5.6 2.7 0.6 6.4 3.0 0.6 6.7 3.2 0.6 8.0 3.7 0.6 9.4 4.3 0.6 10.4 4.7 0.6 10.9 4.9 0.6 12.4 5.6 0.
HEATING EXPANDED RATINGS WITH Coils (Continued) First Stage (Low Speed H1) Heating FT4BG036 or PSH4BG036 Heat Pump matched with C6BH-X36C-C or C6BA-F48(C,U)-C+TXV-X3.0 Coil Outdoor Temperature: Blower cfm 700 800 900 0°F 10° 17° 20° 30° 40° 47° 50° 60° Indoor T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW Tdb 60 7.4 2.6 0.8 9.1 3.1 0.9 10.4 3.4 0.9 11.0 3.6 0.9 13.0 4.1 0.9 15.3 4.8 0.9 16.9 5.2 0.9 17.7 5.5 1.0 20.3 6.2 1.
HEATING EXPANDED RATINGS WITH Coils (Continued) First Stage (Low Speed H1) Heating FT4BG048 or PSH4BG048 Heat Pump matched with C6BH-X48C-C or C6BA-F60(C,U)-C+TXV-X4.0 Coil Outdoor Temperature: 0°F 10° 17° 20° 30° 40° 47° 50° 60° Blower cfm Indoor Tdb 60 7.8 2.7 0.8 9.3 3.0 0.9 10.4 3.3 0.9 10.9 3.4 0.9 12.6 3.8 1.0 14.5 4.3 1.0 15.9 4.6 1.0 16.6 4.7 1.0 18.8 5.3 1.0 750 70 6.7 2.2 0.9 8.3 2.5 1.0 9.5 2.8 1.0 10.0 2.9 1.0 11.8 3.2 1.1 13.7 3.6 1.1 15.1 3.8 1.2 15.8 4.0 1.2 17.9 4.4 1.
HEATING EXPANDED RATINGS WITH Coils (Continued) First Stage (Low Speed H1) Heating FT4BG060 or PSH4BG060 Heat Pump matched with C6BH-X60C-D or C6BA-F60(C,U)-D+TXV-X5.0 Coil Outdoor Temperature: Blower cfm 850 1000 1150 Indoor Tdb 60 70 80 60 70 80 60 70 80 0°F 10° 17° 20° 30° 40° 47° 50° 60° T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW T.C. COP kW 6.4 6.0 5.6 6.8 6.4 6.0 7.2 6.8 6.4 2.5 2.2 1.9 2.5 2.2 1.9 2.6 2.2 1.9 0.7 0.8 0.9 0.8 0.9 0.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Manufactured under license by NORDYNE, O’Fallon, MO. ®Registered Trademark/ TM Trademark of Maytag Corporation or its related companies. ©2012. All rights reserved. 932D-0113 (Replaces 932D-1012) Printed in U.S.A.