Dimension Guide

29⁷⁄₈" (75.9 cm) – 30" (76.2 cm) model
35⁷⁄₈" (91.1 cm) – 36" (91.4 cm) model
7
¹⁄₂
"
(19.1 cm)
2"
(5.1 cm)
1
¹⁄₂
"
(3.8 cm)
1"
(2.5 cm)
1
¹⁄₂
"
(3.8 cm)
6"
(15.2 cm)
9"
(22.9 cm)
12"
(30.5 cm)
³⁄₄"
(1.9 cm)
³⁄₈"
(9.5 mm)
17¹⁄₂"
(44.5 cm)
PRODUCT MODEL NUMBERS
VENTING REQUIREMENTS
UXT5230BD UXT5236BD
Electrical: 120-volt, 60-Hz, AC-only, 15-amp. electrical supply.
Use copper wire only. A time-delay fuse or circuit breaker and
separate circuit is recommended.
Range Hood – 30" (76.2 cm) and 36" (91.4 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10646405
12/14
CABINET OPENING DIMENSIONS
Roof Venting Wall Venting
A. 6" (15.2 cm) round vent or a
(8.3 x 25.4 cm) vent through roof
B. Round vent: use 6" (15.2 cm) round
damper (purchased separately)
C. 18" (45.7 cm) to 24" (61.0 cm)
above cooking surface
D. Roof cap
B. 3¹⁄₄" x 10" (8.3 x 25.4 cm) vent
through the wall
C. 18" (45.7 cm) to 24" (61.0 cm)
above cooking surface
D. Wall cap
A
B
D
C
A
B
C
D
3¹⁄₄" x 10"
A. 6" (15.2 cm) round vent or a
(8.3 x 25.4 cm) vent through wall
3¹⁄₄"
OVERALL DIMENSIONS
36" (91.4 cm)
base cabinet
height
24" (61.0 cm ) min.
30" (76.2 cm)
suggested max.
bottom of hood to
cooking surface
13" (33 cm)
cabinet depth
18" (45.7 cm) min.
24" (61 cm)
suggested max.
bottom of cabinet
to cooking
surface
30" (76.2 cm) or
36" (91.4 cm)
min. cabinet
opening width
3¹⁄₄" x 10" (8.3 x 25.4 cm) vent system
3¹⁄₄" x 10" (8.3 x 25.4 cm) vent system
Maximum length = 35 ft. (10.7 m)
1 - 90° elbow = 5 ft. (1.5 m)
8 ft. (2.4 m) straight = 8 ft. (2.4 m)
1 - wall cap = 0 ft. (0 m)
Length of 3¹⁄₄" x
10" (8.3 x 25.4 cm) system = 13 ft. (3.9 m)
Note: Flexible vent is not recommended
3¹⁄₄" x 10"
(8.3 x 25.4 cm)
90° elbow =
5 ft. (1.5 m)
3¹⁄₄" x 10"
(8.3 x 25.4 cm)
flat elbow =
12 ft. (3.7 m)
3¹⁄₄" x 10"
(8.3 x 25.4 cm)
wall cap =
0 ft. (0 m)
2 ft.
(0.6 m)
6 ft. ( 1.8 m)
wall cap
3¹⁄₄" x 10"
(8.3 x 25.4 cm)
elbow
Maximum length = 35 ft. (10.7 m)
1 - 90° elbows = 5 ft.
(1.5 m)
8 ft. (2.4 m) straight = 8 ft.
(2.4 m)
1 - wall cap = 0 ft.
(0 m)
Length of 7"
(17.8 cm) system = 13 ft.
(3.9 m)
Note: Flexible vent is not recommended
6"
(15.2 cm) v
ent system
3¹⁄₄" x 10"
(8.3 x 25.4 cm) to
6" (15.2 cm) =
4.5 ft. (1.4 m)
90° elbow =
5 ft. (1.5 m)
45° elbow =
2.5 ft. (0.8 m)
3¹⁄₄" x 10"
(8.3 x 25.4 cm)
to 6" (15.2 cm)
90° elbow =
5 ft. (1.5 m)
6" (15.2 cm)
wall cap =
0 ft. (0 m)
elbow
wall
cap
6 ft. (1.8 m)
2 ft.
(0.6 m)
6"
(15.2 cm) v
ent system

Summary of content (1 pages)