ON-BOARD DIAGNOSTIC
End Of Sie
DTC P0480
A6E397001086W04
Diagnostic procedure
DTC P0480 Fan relay control circuit malfunction
DETECTION
CONDITION
PCM monitors cooling fan relay No.2 control signal at PCM terminal 4L. if PCM detects cooling fan relay
No.2 control signal does not change coolant temperature above 100 °
°°
°C {212 °
°°
°F}, PCM determines that
cooling fan relay No.2 control has malfunction.
POSSIBLE
CAUSE
cooling fan relay No.2 malfunction
Connector or terminal malfunction
Open circuit in wiring between METER fuse and cooling fan relay No.2 terminal E
Open circuit in wiring between cooling fan relay No.2 terminal A and PCM terminal 4L
Short to ground in wiring between cooling fan relay No.2 terminal A and PCM terminal 4L
Short to power circuit between cooling fan relay No.2 terminal A and PCM terminal 4L
PCM malfunction
STEP INSPECTION ACTION
1 PERFORM DTC CONFIRMATION PROCEDURE
Perform DTC CONFIRMATION PROCEDURE.
(See F66 DTC CONFIRMATION
PROCEDURE.)
Is same DTC present?
Yes Go to next step.
No Intermittent concern exists. Go to INTERMITTENT
CONCERN TROUBLESHOOTING procedure.
(See F227 INTERMITTENT CONCERN
TROUBLESHOOTING.)
2 INSPECT COOLING FAN RELAY NO.2
CONNECTOR FOR POOR CONNECTION
Turn ignition key to OFF.
Disconnect cooling fan relay No.2 connector.
Inspect for poor connection (damaged/pulled-
out pins, corrosion, etc.).
Is there malfunction?
Yes Repair or replace terminal and/or connector, then go to
Step 9.
No Go to next step.