62 Brocade MLX Series and NetIron Family Documentation Updates
53-1002805-03
Fabric Auto Tuning SNMP and syslog enhancement
1
Message examples
SYSLOG(If no action taken, just logging message):
Apr 30 15:32:16: I: System: Health Monitoring: Fabric link CRC errors:
LP15/TM1/Link4 ? SNM5/FE1/Link16
SYSLOG(If link is shutdown):
Apr 30 15:32:16: I: System: Health Monitoring: Fabric link shutdown due to CRC
errors: LP15/TM1/Link4 ? SNM5/FE1/Link16
SFM Log Message (show sfm log command output when CRC is detected):
Mar 4 20:33:57: Fabric Link CRC errors: LP15/TM1/Link4 ? SNM5/FE1/Link16
SFM Log Message (show sfm log command output when auto tuning
started):
Mar 4 20:33:57: Fabric Link auto tuning started: LP15/TM1/Link4 ? SNM5/FE1/Link16
SFM Log Message (show sfm log command output when auto tuning
finished):
Mar 4 20:33:57: Fabric Link auto tuning completed: LP15/TM1/Link4 ?
SNM5/FE1/Link16
SFM Log Message (show sfm log command output when auto tuning failed):
Mar 4 20:33:57: Fabric Link Shutdown due to auto tuning failure: LP15/TM1/Link4 ?
SNM5/FE1/Link16
SFM Log Message (show sfm log command output based on action taken):
Mar 4 20:33:57: SFM Link CRC Errors: LP3/TM1/Link3 -> SFM1/FE1/Link 15
OR
Mar 4 20:33:57: SFM Link Shutdown due to CRC Errors: LP3/TM1/Link3 ->
SFM1/FE1/Link 15