Technical data

Brocade MLX Series and NetIron Family Documentation Updates 67
53-1002805-03
Management module redundancy overview
1
Syslog messages
The following are examples of Syslog messages that may be displayed.
NP CSRAM has 4 error events, exceeding configured threshold for interfaces 1/1 to
1/24.
NP LPM 1 has 4 error events, exceeding configured threshold for interfaces 1/1 to
1/24.
Management module redundancy overview
The following section is an update to the Management module redunancy overview section of
Chapter 6 in the NetIron 5.4.00 Configuration Guide.
The following paragraph replaces the first paragragh in the referenced section. The defined
active-management module only takes over after a cold reboot (removing power to the chassis),
not a reload.
Corrected text:
When you apply power to a Brocade device with two management modules installed, by default, the
management module in slot M1 becomes the active module and the module in slot M2 becomes
the standby module. (You can change the default active slot from M1 to M2 using the
active-management command. Refer to “Changing the default active chassis slot” on page 199.)
Globally changing the IP MTU
The following note has been added to the section titled “Globally changing the IP MTU” in Chapter
28, Configuring IP.
NOTE
The global IP MTU change does not get applied to IP tunnel interfaces such as GRE interface. The
MTU for these interfaces has to be changed on interface level.