Diagnostic Guide
Management module diagnostics
The management modules control Brocade NetIron XMR and Brocade MLX series hardware
components, run networking protocols, and provide the Real Time Operating System (RTOS).
Each chassis requires one management module, and can accept a second module for redundancy
that works in conjunction with the active management module. If the active management module
becomes unavailable, the redundant management module automatically takes over the system
operation, minimizing system downtime.
Running management module diagnostics
You can run diagnostics on the management modules to check if the devices needed for proper
operation are accessible and in working order. The diagnostics for the Line Processor (LP) modules
begin after the completion of diagnostics for the management processor (MP) modules, if the LP
modules are present in the chassis.
MP module is considered to have passed the diagnostics if the result of all the checks is "Passed".
If an MP or an LP does not pass the diag burn-in command, contact Brocade Technical Support for
further assistance.
NOTE
Remove the standby management module from the chassis before running the diagnostics. If the
standby management module is present, running the diagnostics on the interface module fails.
To run diagnostics on management modules, perform the following steps.
1. Reload the system and immediately press the B key repeatedly until the system boots into
monitor mode.
2. Type boot os flash primary to enter the OS.
The prompt will change from MP Monitor> to MP OS>.
3. From the MP OS> prompt, enter diag burn-in, as shown in the following example.
MP-1 OS>diag burn-in
PCI access - Passed
88E1145 PHY - Passed
Storage Card - Passed
M41T11 RTC - Passed
FE (slot 0; FE 0; 0x11fe6000) access passed;
FE (slot 0; FE 1; 0x11fe6000) access passed;
FE (slot 0; FE 2; 0x11fe6000) access passed;
FE (slot 1; FE 0; 0x11fe6000) access passed;
FE (slot 1; FE 1; 0x11fe6000) access passed;
FE (slot 1; FE 2; 0x11fe6000) access passed;