Technical Specifications Power Fuse Lamps Dimension Weight AC 120V 60Hz Clrcuit breaker 15A J Type 120V 300W 450mm x 270mm x 175mm 7 kg / 15.
7. Fixture Cleaning The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit ’s optics. * Clean with soft cloth using normal glass cleaning products. * Always dry the parts carefully. * Clean the external optics at least once every 20 days.
6. Troubleshooting Following are a few common problems that may occur and suggestions as to how to solve them. INDEX A. No light 1. General Instructions 1. Check the power on LED and fuse 2. Check the lamp if it is ok? (The lamp may turn off, when the unit is in blackout). 2. Main Features B. Not responding to DMX 1. Check red LED is on, if not, check DMX connectors, cables and linking correctly. 3. Lamp 2.
1. Getting Instructions D. By universal DMX controller The following points are important for safety as well as for the smooth installation and If you use a universal DMX controller to control the units, you have to set dip switches performance of the unit. from 1 to 9 of the channel so that all the units will receive its DMX signal. Please refer to the following diagram to know how to address your DMX512 system in the binary code.
C. By Colormix controller 2. Main Features Voltage:AC 120V By link the Colormix controler to the unit , you have to use 3 pin XLR cable and use 5 60 Hz • Bulb: J Type 120V 300W pin XLR cable between Colormix controller and Colormix foot controller. • 3 dichroic mirrors red, blue, and green or 4 dichroic mirrors red, yellow, blue, and green. • With lamp saving switch-off function.
4. DMX Link & Controls 5. How To Control The Unit You can operate the unit in four ways: A. By master/slave preprogrammed function By linking the units in master/slave connection, Channel Dip switches setting Master Slave 1 ON 1 2 3 4 5 6 7 8 9 10 the first unit will control the other units to give an automatic activated synchronized light show. In this Slave 2 Slave 3 mode, the first unit(master)dipswitch 10 must be on.