Series I Reach-Ins with Aluminum Interior Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 3.
McCall Series I Reach-In Manual Important Warning And Safety Information WARNING Read this manual thoroughly before operating, installing, or performing maintenance on the equipment. FAILURE TO FOLLOW INSTRUCTIONS IN THIS MANUAL CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. UNLESS ALL COVER AND ACCESS PANELS ARE IN PLACE AND PROPERLY SECURED, DO NOT OPERATE THIS EQUIPMENT.
McCall Contents Serial Number........................................................................3 Receiving And Inspecting The Equipment.............................3 Model Numbers.....................................................................4 Introduction...........................................................................5 Serial Number Location The serial number is on the identification plate that also includes the model number. A typical identification plate is shown below.
McCall Series I Reach-In Manual Model Numbers Series Temp Configuration Section Doors MCC = McCall Reach-In R=Refrigerator F=Freezer H=Heated D=Dual Temp None=Reach-in PT=Pass Thru RL=Refrigerator Left TR=Top Refrigerator 1=1 Section 2=2 Section 3=3 Section S=Solid Full SH=Solid Half SLG=Sliding Glass Full G=Hinged Glass Full GH=Hinged Glass Half
McCall Introduction McCall reach-in models have an aluminum interior and exterior with a stainless steel front and shroud. Door gaskets are magnetic and mount to the door, snapping in place and are removable without tools. Keyed door lock is mounted in the door next to the handle. Doors can be removed from the cabinet without the use of tools. Each door has two edge mount, self-closing, cam lift style hinges.
McCall Series I Reach-In Manual Specifications Reach-In Refrigerators - Hinged Doors - Standard Width & Depth Voltage Amps Storage Capacity Ft3 Shelf Capacity Ft2 No. Of Shelves H.P. BTU/HR R-404A Charge Oz. Shipping Weight NEMA Plug Energy (KWH) MCCR1-S,SH,G,GH 115 6.8 24.96 12.81 3 1/4 2092 12.5 418lbs/ 190kg 5-15P 2.64 MCCR2-S,SH,G,GH 115 9.0 51.92 27.54 6 1/3 3226 19 650lbs/ 295kg 5-15P 4.51 MCCR3-S,SH,G,GH 115 16.0 78.89 42.
McCall Specifications, continued Pass-Thru Refrigerators - Hinged Doors - Standard Width Voltage Amps Storage Capacity Ft3 Shelf Capacity Ft2 No. Of Shelves H.P. BTU/HR R-404A Charge Oz. Shipping Weight NEMA Plug Energy (KWH) MCCRPT1-S,SH 115 6.8 26.64 12.81 3 1/4 2092 12.5 455lbs/ 206kg 5-15P 3.14 MCCRPT1-G,GH 115 7.8 26.64 12.81 3 1/3 2488 12.5 455lbs/ 206kg 5-15P 4.58 MCCRPT2-S,SH 115 16.0 55.42 27.54 6 1/2 5465 24 700lbs/ 318kg 5-20P 5.
McCall Series I Reach-In Manual Installation Location Cabinets represented in this manual are intended for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet, 1000 pounds (450 kg) per door section. Reinforce the floor if necessary to provide for maximum loading. For the most efficient operation, be sure to provide good air circulation inside and out. The location should be selected so that the power cord can be connected without any extensions.
McCall Installation, continued Electrical Connection Refer to the amperage data list in the SPECIFICATIONS or the serial tag data and your local code or the National Electrical Code to be sure the unit is connected to the proper power source. A protected circuit of the correct voltage and amperage must be run for connection of the supply cord or permanent connection to the unit. The power must be turned off and disconnected whenever performing maintenance or repair functions.
McCall Series I Reach-In Manual Electronic Temperature Control Operation The electronic temperature control constantly monitors box temperature as well as evaporator coil temperature to maintain consistent product temperatures. The control also sends temperature readings to the digital temperature display. The control circuits continually self-check and if an error occurs, the digital display will switch from temperature read-out to error read-out, i.e. E1.
McCall Heated Cabinet Operation The Heated units have a POWER ON/OFF switch located behind the flip up shroud at the front top of the unit for controlling power to the unit and an electronic thermostat for setting the temperature. A circulating fan provides uniform airflow in the cabinet. Power Up 1. 2. 3. 4. 5. Check that unit is properly connected to the power source. Raise the shroud to access the controls. Set the Main POWER ON/OFF switch, to the ON position.
McCall Series I Reach-In Manual Maintenance Door Gasket Maintenance Door gaskets require regular cleaning to prevent mold and mildew build up and also to retain the elasticity of the gasket. Gasket cleaning can be done with the use of warm soapy water. Avoid full strength cleaning products on gaskets as this can cause them to become brittle and crack. Never use sharp tools or knives to scrape or clean the gasket.
McCall Maintenance, continued Do not place hot pans on/against the grey ABS door liner. Do not throw items into the storage area. Failure to follow these recommendations could result in damage to the interior of the cabinet or to the blower coil. Overloading the storage area, restricting the airflow, and continuous opening and closing of the doors and drawers will hamper the units ability to maintain operational temperature.
McCall Series I Reach-In Manual Refrigerator Wiring Diagrams MCCR1, MCCRPT1 - Solid Doors ./4%3 53% #/00%2 #/.$5#4/23 /.,9 4()3 5.)4 -534 "% '2/5.$%$ 5.)4 3(/7. 7)4( #/-02%33/2 25..).' !.$ $//23 #,/3%$ , . ,).% 6/,4!'% 3%% .!-%0,!4% &/2 -!8)-5&53% 3):% %6!0/2!4/2 (/53).' %6!0 &!. -/4/2 - 0,5' . #/.42/, #)2#5)4 # ",5% - #/-02%33/2 2%,!9 ).#!.$%3#%.4 ,)'(4 #/-02%33/2 7 %.%2'9 3!6%2 37)4#( 7 7)4( ",5% 342)0%3 7)2% .54 7 #/.
McCall Refrigerator Wiring Diagrams MCCR2 - Solid Doors MCCR2, MCCR2-SL - Glass Doors 15
McCall Series I Reach-In Manual Refrigerator Wiring Diagrams MCCRPT2, MCCR3 - Solid Doors MCCRPT2, MCCR3 - Glass Doors 16
McCall Freezer Wiring Diagrams MCCF1 - Solid Doors , . ,).% 6/,4!'% 3%% .!-%0,!4% &/2 -!8)-5&53% 3):% ./4%3 53% #/00%2 #/.$5#4/23 /.,9 4()3 5.)4 -534 "% '2/5.$%$ 5.)4 3(/7. 7)4( #/-02%33/2 25..).' !.$ $//23 #,/3%$ %6!0/2!4/2 (/53).' %6!0 &!. -/4/2 9 . ",5% & &!. 2%,!9 0,5' - $%&2/34 (%!4%2 %6!0 #/), 3%.3/2 #/.42/, #)2#5)4 #!").%4 !)2 3%.3/2 , ()'( 4%-0 ,)-)4 37)4#( - 4%-0%2!452% #/.42/, 7 %6!0/2!4/2 &!. ).#!.$%3#%.
McCall Series I Reach-In Manual Freezer Wiring Diagrams MCCF2 - Solid Doors MCCF2, MCCF3 - Glass Doors PDF created with pdfFactory trial version www.pdffactory.
McCall Freezer Wiring Diagrams MCCF3 - Solid Doors Refrigerator/Freezer Combination Wiring Diagram MCCDTR1 - Solid Doors 19
McCall Series I Reach-In Manual Heated Models Wiring Diagram MCCH1, MCCH2, MCCH3 - Solid & Glass Doors 20
McCall Compressor Diagrams Capacitor, start Relay & Overload Valve, EXP Compressor Drier, filter Motor, fan, evaporator Motor, fan, condensor Blade, fan Guard, fan, condenser Coil, condenser Coil, evaporator Fan delay, defrost limit Blade, fan, condenser Guard, fan, condenser Coil, evaporator Coil, condenser Valve, EXP Motor, fan, evaporator Compressor Relay & Overload Blade, fan Capacitor, start Fan delay, defrost limit Heater, defrost Switch Control switch Drier, filter 21
McCall Series I Reach-In Manual Replacement Parts MCCR1, MCCRPT1, MCCDRL2, - Solid Doors MCCR1, MCCDRL2 - Glass Doors MCCRPT1 - Glass Doors Part Number Description Part Number Description 3516433 Blade, Fan, 25 3516432 Blade, Fan, 25Deg, 8.75" 3517390 Blade, Fan, 5.56, CW, Lexan 3517390 Blade, Fan, 5.
McCall Replacement Parts, continued MCCF1, MCCDRL2 - Solid Doors MCCDRL2 - Glass Doors MCCF2 - Solid Doors Part Number Description Part Number Description 3516433 Blade, Fan, 25 3516432 Blade, Fan, 25DEG, 8.75" 3516204A Breaker, Vacuum 3517390 Blade, Fan, 5.56, CW, Lexan 3516442 Capacitor, Start, Run, Assy 3516204A Breaker, Vacuum 3517340 Coil, Evap, Sml FRZ, 2dr, Up 2194789 Capacitor, Start, 240MFD 3527002 Comp, SC18CLX.
McCall Series I Reach-In Manual Replacement Parts, continued MCCF3 - Glass Doors All Heated Models Part Number Description Part Number Description 3517390 Blade, Fan, 5.
McCall Standard Labor Guidelines To Repair Or Replace Parts On McCall Equipment Advice and recommendations given by McCall Service Technicians do not constitute or guarantee any special coverage. • A maximum of 1-hour is allowed to diagnose a defective component. • A maximum of 1-hour is allowed for retrieval of parts not in stock. • A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.
McCall Series I Reach-In Manual Standard One Year Limited Warranty (One year parts and labor, five year compressor) McCall warrants to the Original Purchaser of the McCall product (herein called the “Unit”) that such Unit, and all parts thereof, will be free from defects in material and workmanship under normal use and service for a period of one (1) year from the date of shipment of the Unit to the Original Purchaser or, if the Original Purchaser returns the warranty card completely filled out including t
McCall Additional Four Year Protection Plan (for motor-compressor only) In addition to the Standard One Year Warranty on the Motor Compressor contained in the above listed McCall product (the “Unit”), McCall also agrees to repair, or exchange with similar or interchangeable parts in design and capacity at McCall’s option, the defective Motor-Compressor contained in the Unit (the “Motor-Compressor), or any part thereof, for the Original Purchaser only, at any time during the four (4) years following the i
Thank you for choosing McCall! Help is a phone call away. Help our team of professional, courteous customer service reps by having your model number and serial number available at the time of your call (800) 733-8829. Model:_____________________ S/N: ____________________ Installation Date:_____________ For a list of McCall’s authorized parts depots, visit our website at www.mccallrefrigeration.com. 980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A. • (888) 732-2446 • Fax (800) 669-0619 • www.