Specifications
panel thicknesses.
Insert a screw in the center holes ("B"
holes). Tighten so that the screw pulls into
the wood.
5. Prepare the equipment by: (A) removing
the shipping skid attached to the chassis,
(B) removing the four plastic feet fastened
under the chassis, and (C) removing the two
metal panel end caps from the front panel by
pulling them sidewise away from the panel.
Note, the metal end caps may have been
packed separate, already removed from the
front panel: if this is the case, disregard this
last instruction.)
6. Insert the power cord through the open-
ing. Slide the unit fully into the cabinet.
7. Secure the MI-2 to the panel using 4 of
the fillister head machine screws. These
screws should pass through the MI-2 flange,
through the wood panel, and into the fasten
ing strip attached to the inside of the panel
The screws should be moderately tightened.
Finally attach the end caps to the MI-2
panel by sliding them onto the pins projecting
from the panel ends. Spring tension will hold
the end caps in position.
MOUNTING IN THE L10W AND
L10W0 CABINET
The Mclntosh L10W and L10W0 cabinets
are supplied with complete instructions and
all necessary hardware for installing the
MI-2 Indicator.
The dimensions of the L10W and L10W0
cabinets are 17 inches wide by 6
5
/
8
inches
high, including mounting feet, by 14
3
/
8
inches
deep including tuner front panel and control
knobs.
CONNECTING
TWO PAIRS OF 3 FOOT LONG LOW-LOSS
SHIELDED CABLES ARE SUPPLIED WITH
THE MI-2. USE THESE CABLES TO CONNECT
THE MI-2 TO A TUNER FOR MULTIPATH
INDICATION. A PAIR OF 6 FOOT LONG
SHIELDED CABLES ARE SUPPLIED FOR
CONNECTING THE MI-2 IN AUDIO CIR-
CUITS.
CONNECTING TO MclNTOSH MR67 TUNER
Connect a 3 foot low-loss shielded cable
from the MR67 TP1 (Test Point 1 jack on top
of the tuner chassis to the Signal Strength
(vertical) Input on the MI-2.
Connect a second 3 foot low-loss shielded
cable from the MR67 TP2 (Test Point 2 jack
on top of the tuner chassis) to the Deviation
(horizontal) Input on the MI-2.
CONNECTING TO MclNTOSH MX 110
TUNER-PREAMPLIFIER WITH Z OR X
SERIAL NUMBERS
Connect a 3 foot low-loss shielded cable
from the MX110 TP1 (Test Point 1 jack on
top of the tuner chassis) to the Signal Strength
(vertical) Input on the MI-2.
Connect a second 3 foot low-loss shielded
cable from the MX110 TP2 (Test Point 2 jack
on top of the tuner chassis) to the Deviation
(horizontal) Input on the MI-2.
8
Figure 15. Fitting the End Caps to the Panel.
Figure 14. Securing Mounting Strips To
Installation Cutout.