Owner`s manual

32
INSTALLER MENU SUB MENU SELECTION OPTION(S) DESCRIPTION SETUP SHEET NO.
Zone B Setup
Edit Zone B Sources
Audio In None, Balanced 1-2, Stereo
1-8, Phono
Zone B analog audio input source 5
Data Out None, Data Port 1-8 Assign a data port output different from Zone A 5
RC Button Remote Control direct access
Push-buttons
Assign a Remote Control Push-button different
from Zone A
5
System Setup
Video Setup
Analog Out NTSC, PAL Sets the Composite and S-Video video output
signal standard
6
Component Out YPbPr, RGB Sets the type of video output signal 6
Component In 1 YPbPr, RGB Sets the type of video input signal 6
Component In 2 YPbPr, RGB Sets the type of video input signal 6
Component In 3 YPbPr, RGB Sets the type of video input signal 6
Component In 4 YPbPr, RGB Sets the type of video input signal 6
Component In 5 YPbPr, RGB Sets the type of video input signal 6
Serial Setup
Baudrate 9600, 19200, 38400, 57600 or
115200
Sets kilobit speed for RS232 Data Port 6
HW Handshake No, Yes Use Hardware Handshake for the RS232 Data
Port
6
Feedback 0, 1, 2 Set the degree of feedback from the control
device connected to the RS232 Data Port
6
Network Setup
Mode Manual IP, Automatic
(DHCP), disable
Enter manually (the IP address, subnet Mask
and Gateway), or Automatic setup with network
using Dynamic Host Conguration Protcol, dis-
able network connections
6
IP 192.168. 1.222 IP Address 6
Mask 255.255.255. 0 Subnet Mask 6
GW 192.168. 1. 1 Gateway 6
Note: For MX151 WEB Interface perform the following; first connect MX151 to the PC Computer Ethernet Network, second enter Setup Mode, third select “System Setup” → “Net-
work Setup”, fourth select Automatic (DHCP), fifth select save, sixth copy the IP address shown On-Screen to the address line (after http://) of the WEB Browser.